A fix is available
APAR status
Closed as program error.
Error description
Current CP CPU time is always = 0 in ZTDL despite the thread status is IN-DB2 + + In-DB2 Times Total Current + ------------------------------ ------------ ------------ + Elapsed Time 00:20:24.474 00:00:00.002 + CP CPU Time 00:06:25.374 00:00:00.000 + Stored Procedure CPU Time 00:00:00.000 00:00:00.000 +
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: CURRENT CP CPU TIME VALUE IS ALWAYS * * ZERO IN IN-DB2 TIMES SECTION OF ZTDTL * * SCREEN * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Current in-DB2 CPU time is incorrect PROBLEM CONCLUSION: Use IFCID 124 data to populate current in-DB2 CPU time and in-DB2 elapsed time. Data collection requires class 9 monitor trace.
Problem conclusion
Use IFCID 124 data to populate current in-DB2 CPU time and in-DB2 elapsed time. Data collection requires class 9 monitor trace. KEYWORDS : IFCID 124 DB2 CPU TIME DB2 ELAPSED TIME ZTDTL
Temporary fix
Comments
APAR Information
APAR number
PK61040
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-02-14
Closed date
2008-06-04
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK37054
Modules/Macros
KD2VTHD6 KD20THD6 KO2APCBA KO2APCBS KO2APCB2 KO2APC1A KO2APC1S KO2APC12 KO2APC2A KO2APC2S KO2APC22 KO2APC4A KO2APC4S KO2APC42 KO2CCINB KO2CDFCA KO2CDFCS KO2CDFC2 KO2CLKDA KO2CLKDS KO2CLKD2 KO2CSYSA KO2CSYSS KO2CSYS2 KO2CTHSA KO2CTHSS KO2CTHS2 KO2CTH2A KO2CTH2S KO2CTH22 KO2CTH3A KO2CTH3S KO2CTH32 KO2CTH5A KO2CTH5S KO2CTH52 KO2CTH8A KO2CTH8S KO2CTH82 KO2CT2IA KO2CT2IS KO2CT2I2 KO2CT2SA KO2CT2SS KO2CT2S2 KO2NCSTB KO2OSYXB KO2OTHAB KO2OTHXB KO2OXSYB KO2OXTHB KO2TDTLH KO2WNCYB KO2XSYSA KO2XSYSS KO2XSYS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK37054
UP08/06/06 P F806
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017