IBM Support

PK59371: RECURSIVE ABENDS KO2CDB22 DIFFERENT OFFSETS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After taking initial abends in KO2CDB22
    the product begins taking recursive abends and messages similar
    to the following are seen in the joblog
    OMEGAMON II FOR DB2 DUMP:  TASK=COMMCOLL,ID=V410
     ,MOD=KO2CDB22,OFFSET=01CFD0,CODE=S0C4/00000011
    OMEGAMON II FOR DB2 DUMP:  TASK=COMMCOLL,ID=V410
     ,MOD=KO2CDB22,OFFSET=019A9E,CODE=S0C4/00000011
    Addtional symptoms:
    ABEND0C4 rc11 KO2CTHS2+4350 (PK52692) D501 2000 A4AA
                  (CLC instruction)
    ABEND0C4 rc11 KO2CTHS2+E1E  (PK52692) D503 2004 A268
                  (CLC instruction)
    ABEND0C4 rc04 KO2XTHS2+2460 (PK41819) D2FF 2258 5100
                  (MVC instruction)
    

Local fix

  • Recycle the collector task
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON Server                          *
    *                 -   Common Collector                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Recursive ABEND0C4'S in                 *
    *                      Load Module KO2ACONB.                   *
    *                                                              *
    *                      KO2I0170U S0C4 ABEND IN                 *
    *                      MODULE KO2CDB2S PERCOLATED TO           *
    *                      D5API.                                  *
    *                                                              *
    *                      ABEND0C1's in KO2ACONB                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF                                *
    ****************************************************************
    PROBLEM SUMMARY:
    The IFI subtask is inactive and lock conflict storage areas
    that are being referenced have been released.
    
    KO2ACONB Error Recovery Logic in error
    
    Invalid parm passed to THTCPTIM routine
    
    PROBLEM CONCLUSION:
    Ensure the IFI TCB is active before the common collector
    invokes the table drivers.
    KO2ACONB Error recovery has been corrected.
    Pass correct parameter to THTCPTIM routine
    

Problem conclusion

  • Ensure the IFI TCB is active before the common collector
    invokes the table drivers.
    KO2ACONB Error recovery has been corrected.
    
    Pass correct parameter to THTCPTIM routine
    
    
    KEYWORDS :
    KO2CDB22 RECURSIVE ABEND0C4 IFI SUBTASK XLKD APCB KO2XDB22
    KO2CAPI2 HIPER ERROR RECOVERY
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK59371

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-01-15

  • Closed date

    2008-03-04

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK33702 UK33703

Modules/Macros

  •    KO2ACONB KO2AINIB KO2AOMBB KO2APCAA KO2APCAS
    KO2APCA2 KO2APCBA KO2APCBS KO2APCB2 KO2APCCA KO2APCCS KO2APCC2
    KO2APC1A KO2APC1S KO2APC12 KO2APC2A KO2APC2S KO2APC22 KO2APC3A
    KO2APC3S KO2APC32 KO2APC4A KO2APC4S KO2APC42 KO2APC5A KO2APC5S
    KO2APC52 KO2APC9A KO2APC9S KO2APC92 KO2ARECB KO2DATA  KO2XLKDA
    KO2XLKDS KO2XLKD2
    

Publications Referenced
GC18998001SC18963801   

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK33702

       UP08/03/08 P F803 Ž

  • R410 PSY UK33703

       UP08/03/08 P F803 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: