IBM Support

PK59359: IPI0024E STATISTICS RECORD HAS AN INVALID LENGTH

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGIPI0024E is issued due to a change that was made in an IMS
    macro DFSRSTAT.  The change was made by IMS V9 APAR PK31523
    (Oct 2007) which extended the length of the x'4522' record.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS Performance analyzer V4.1 users.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: IPI0024E Statistics record has an       *
    *                      invalid length.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IPI0024E Statistics record has an invalid length caused by a
    change to IMS macro DFSRSTAT in PK31523 (Oct 2007) which
    extended the length of the x'4522' record.
    

Problem conclusion

  • Re-assemble IPISIRUR with latest IMS.SDFSMAC
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK59359

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-01-15

  • Closed date

    2008-02-14

  • Last modified date

    2008-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK33708

Modules/Macros

  • IPI#RSLV IPIFCOMD IPIFTCMD IPIRFMET IPISIRUR
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R410 PSY UK33708

       UP08/02/19 P F802

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: