Error description

  • QMF V81 message  DSQ20712 when issuing QBE DRAW
    command with synonyms.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All QMF TSO/CICS V810 and V910 QBE users     *
    *                 who use tablename synonyms.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message DSQ20712 "DRAW  needs a valid   *
    *                      name." is issued if the DRAW command    *
    *                      is issued with a tablename synonym      *
    *                      in QBE.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When long name support was added to QMF in version 81, code
    was added to check the length of table owner names, as in
    the high level qualifier of the table name--USERID.TABLENAME.
    If a tablename has a synonym, the field that would contain the
    owner name is set to blanks but the field that contains the
    length of the owner name was not set to zero.  This mismatch
    ultimately led to the error condition.
    

Problem conclusion

  • Code was added to reset the owner name length to zero when
    the owner name is set to blanks.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK59113

  • Reported component name

    QMF-QUERY MGMT

  • Reported component ID

    566872101

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-01-10

  • Closed date

    2008-01-18

  • Last modified date

    2008-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK33076 UK33077

Modules/Macros

  • DSQEBOR  DSQFBOR  DSQIBOR
    

Fix information

  • Fixed component name

    QMF-QUERY MGMT

  • Fixed component ID

    566872101

Applicable component levels

  • R810 PSY UK33076

       UP08/01/22 P F801

  • R910 PSY UK33077

       UP08/01/22 P F801