IBM Support

PK58334: WAIT IN HFPAS4I0 AT X'154' DUE TO ENQ/DEQ ISSUES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1. Wait in HFPAS4I0 at x'154' due to ENQ/DEQ issues.
    2. ABEND0CB running FPA ANALYZE function. PSW points to
    HFPA5H20 + x'0352'. Keyword: ABENDS0CB
    
    This is a forward fit of HPFPU V3R1 FPA APAR PK56899.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Fast Path Advanced Tool         *
    *                 Version 3 Release 2. (FMID: H31A320)         *
    ****************************************************************
    * PROBLEM DESCRIPTION: FPA functions can hang due to ENQ/DEQ   *
    *                      issues for the internal buffer.         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    Forward Fit APAR of FPA V3R1 PK56899:
    Two issues:
    1. The following FPA functions can hang due to ENQ/DEQ issues
       for the internal buffer.
         - ANALYZE with PTRCHKLVL=FULL
         - CHANGE
         - EXTRACT
         - RELOAD with PTRCHKLVL=FULL
         - REORG
         - UNLOAD
    2. ABEND0CB in HFPA5H20 can occur.
    

Problem conclusion

  • HFPRSRB0 has been modified to manage the internal buffer
    properly.
    HFPA5H20 has been modified not to cause the decimal-divide
    exception.
    320Y
    HFPA5H20
    HFPA5IN0
    HFPA5WKG
    HFPA5000
    HFPRSRB0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK58334

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-12-17

  • Closed date

    2008-01-16

  • Last modified date

    2008-03-04

  • APAR is sysrouted FROM one or more of the following:

    PK56899

  • APAR is sysrouted TO one or more of the following:

    UK32985

Modules/Macros

  •    HFPA5H20 HFPA5IN0 HFPA5WKG HFPA5000 HFPRSRB0
    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R320 PSY UK32985

       UP08/02/04 P F802

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 March 2008