Error description
The status code is not displayed when the application program for the Load API function abends.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210) * **************************************************************** * PROBLEM DESCRIPTION: The status code is not displayed when * * the application program for the Load * * API function abends. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the application program for the Load API function abends, IMS-AID DIAGNOSTICS of ABEND-AID is not displayed and status code cannot be checked.
Problem conclusion
The Load API function has been modified to display the PCB and call parameter list, when the application program abends. ======================== = Documentation Change = ======================== IMS High Performance Load for z/OS Version 2 Release 1 User's Guide SC18-9222-02 ( SC18922202 ) should be changed as follows: ---------------------------------------------------------------- 4.0 Load API 4.2 Operating instructions 4.2.4 Input--Control statements 4.2.4.5 TRACE control statement Specify where to write the trace data. This statement is optional. If you do not explicitly specify this control statement, TRACE=NO is used. ____________________________________________________________ | | | _NO____________________ | | >>__TRACE=__|_YES_ ______________ __|___________________>< | | | |_,StartNumber_| |_,SNAP_| | | | |____________________________________________________________| YES Writes the trace records. NO Does not write the trace records. StartNumber Specifies the starting number of the calls to be traced. If you specify '100', the trace records of the calls from 100th to the last are displayed. | SNAP | Displays the information of the call function, I/O area, | and SSAs when the Load API function ends with ABENDU4000. To define the output location for the trace record, specify HPSRTRAC DD. ... 4.2.5 Output |4.2.5.3 Application Abend Snap report | | This report contains the information for the problem | determination of the application program. It is produced in | the HPSRTRAC DD, when the Load API function ends with | ABENDU4000. | | Each can be described as follows: | STATUS CODE | The status code returned in the PCB. | APPL-PCB | The PCB which is used by the application program. | | The following are displayed only when the SNAP option is | specified in the TRACE control statement: | | FUNCTION CODE | The function code which is passed from the application | program. | I/O AREA | The I/O area which is passed from the application | program. | SSA-nn | The SSAs which is passed the application program. | | Note: If the application program abends by parameter list | error (status $1 or AH), Load API function does not | display the information of the I/O area and SSAs.
Temporary fix
Comments
APAR Information
APAR number
PK58296
Reported component name
IMS HIGH PERF L
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-12-15
Closed date
2008-02-07
Last modified date
2008-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK33544
Modules/Macros
FABFLINK HPSRADLI HPSRAT00 HPSRAULA HPSRAUL0 HPSRAUL7 HPSRAUL8 HPSRAUL9 HPSRDSCT HPSRFCA0 HPSRHALA HPSRHALM HPSRHAL7 HPSRHAL8 HPSRHAL9 HPSRHDLA HPSRHDLD HPSRHDL7 HPSRHDL8 HPSRHDL9 HPSRHSLA HPSRHSLD HPSRHSL7 HPSRHSL8 HPSRHSL9 HPSRHTBL HPSRLACA HPSRRLDA HPSRRLDM HPSRRLD7 HPSRRLD8 HPSRRLD9 HPSRRPTH HPSRRRIN HPSRRRI0 HPSRRRI9 HPSRSTMT HPSRTRCA HPSRTRCW HPSRTRC7 HPSRTRC8 HPSRTRC9 H1IM210J
| SC18922202 |
Fix information
Fixed component name
IMS HIGH PERF L
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UK33544
UP08/02/09 P F802
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]