A fix is available
APAR status
Closed as program error.
Error description
Running a statistics batch report with the following: GLOBAL INTERVAL(30) STATISTICS REPORT LAYOUT(LONG) DDNAME(STRPT1) REPORT LAYOUT(LONG) ORDER(INTERVAL) DDNAME(STRPT2) . Results are incorrect. The CREATE INDEX and DROP TABLE fields in the interval report DO add up to the value as presented in the STRPT1, however the DECLARE GLOBAL TEMP TABLE field does not. DSNZPARM STATIME=30 parameter is set in DB2 subsystem. When running the report with the INTERVAL option removed from the GLOBAL, the totals results are good.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: Values for DECLARE GLOBAL TEMP TABLE * * are inaccurately shown in statistics * * reports using the INTERVAL option. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Values for DECLARE GLOBAL TEMP TABLE are inaccurately shown in statistics reports using the INTERVAL option. PROBLEM CONCLUSION: Correct interval calculation. KEYWORDS: DECLARE GLOBAL TEMP TABLE
Problem conclusion
Correct interval calculation. KEYWORDS: DECLARE GLOBAL TEMP TABLE
Temporary fix
Comments
APAR Information
APAR number
PK58086
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-12-12
Closed date
2007-12-18
Last modified date
2008-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PK58240 UK32395 UK32396
Modules/Macros
DGOSACU2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: