IBM Support

PK57310: KO2O1421E NEAR-TERM HISTORY DATA COLLECTOR - WORKLOAD DANALYZE HAD LOOPED MORE THAN TEN TIMES. TERMINATING (SERVLOOP)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2O1421E NEAR-TERM HISTORY DATA COLLECTOR - WORKLOAD DANALYZE
    HAD LOOPED MORE THAN TEN TIMES. TERMINATING (SERVLOOP).
    

Local fix

  • The workaround is to periodically stop and re-start the
    historical collector.  This may be done by commands:  /F O2CI,P
    H2xxxx and /F O2CI,EXEC STRTxxxx where "xxxx" is a DB2 SUBSYSTEM
    name.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON Server                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: High CPU and storage usage caused by    *
    *                      growing linked list processing error.   *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Incorrect assumptions regarding timestamp values in the DB2
    accounting records.
    
    PROBLEM CONCLUSION:
    Recognize the timestamp value as an elapsed time value.
    

Problem conclusion

  • Recognize the timestamp value as an elapsed time value.
    
    KEYWORDS : MSGKO2O1421E ABENDC78 DANALYZE WORKLOAD CPU
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK57310

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-11-29

  • Closed date

    2008-01-18

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA23761 UK33061 UK33062

Modules/Macros

  •    KO2DTHDA KO2DTHDS KO2DTHD2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK33061

       UP08/01/22 P F801 Ž

  • R410 PSY UK33062

       UP08/01/22 P F801 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017