Error description
Wait in HFPAS4I0 at x'154' due to ENQ/DEQ issues. Additional issue fixed: ABEND0CB running FPA ANALYZE function. PSW points to HFPA5H20 + x'0352'. Keyword: ABENDS0CB
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Fast Path Advanced Tool * * Version 3 Release 1. (FMID: H31A310) * **************************************************************** * PROBLEM DESCRIPTION: FPA functions can hang due to ENQ/DEQ * * issues for the internal buffer. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Three issues: 1. The following FPA functions can hang due to ENQ/DEQ issues for the internal buffer. - ANALYZE with PTRCHKLVL=FULL - CHANGE - EXTRACT - RELOAD with PTRCHKLVL=FULL - UNLOAD 2. After applying APAR PK56312/UK31607, the meaningless information about SDEP segment is appeared in the DEDB Area Analysis reports when the ANALYZE function is run for an area that has SDEP segments. 3. ABEND0CB in HFPA5H20 can occur.
Problem conclusion
HFPRSRB0 has been modified to manage the internal buffer properly. HFPA5000 has been modified not to report the information about SDEP segment in the DEDB Area Analysis reports. HFPA5H20 has been modified not to cause the decimal-divide exception. 310Y HFPA5H20 HFPA5IN0 HFPA5WKG HFPA5000 HFPRSRB0
Temporary fix
Comments
APAR Information
APAR number
PK56899
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-11-20
Closed date
2007-12-05
Last modified date
2008-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK31965 PK58334
Modules/Macros
HFPA5H20 HFPA5IN0 HFPA5WKG HFPA5000 HFPRSRB0
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R310 PSY UK31965
UP07/12/07 P F712
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 January 2008