IBM Support

PK56487: AFTER QCF PARSING ERROR IN IMS REGION, IMS MUST BE RECYCLED SINCE THERE'S NO COMMUNICATIONS WITH THE TSO CLIENT THERAFTER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • After a QCF parsing error in the IMS control region, IMS must be
    recycled since there is no communications with the TSO client
    thereafter.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All QCF PROCLIB users.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: New syntax checker function for QCF     *
    *                      PROCLIB members.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    New syntax checker function for QCF PROCLIB members.
    The QCF Users Guide will be updated to have next
    information:
     INSTALLING AND CONFIGURING QCF SYNTAX CHECKER
    
     CUSTOMIZING AND STARTING THE QCF CONFIG FILE SYNTAX CHECKER
    
      IMS QCF Config File Syntax Checker performs syntax checking of
      either a QCF Server or QCF Extension Configuration File.  The
      QCF Config File Syntax Checker communicates with the IMS Base
      Primitive Environment (BPE) services to perform a portion of
      this function.
    
      The QCF Syntax Checker users the BPE parsing service to parse
      the configuration data and then does additional validation.
      The QCF Syntax Checker parsing stops parsing on the first
      syntax error it encounters.  A BPE error message is issued
      with the line number and character number of  where the
      parsing error occurred.   In addition, the Syntax Checker will
      perform additional validation.
    
      Before you start the QCF Server address space or before
      starting the IMS environment, the QCF Server and QCF Extension
      Configuration files that are stored as PROCLIB member can be
      syntax validated to remove the possibility of having to
      recycle either the QCF Server or the IMS environment
    
      CONFIGURING AND SUBMITTING THE QCF SYNTAX CHECKER JCL
    
      The  hlqual.siqcsamp(IQCSYNTX) member contains
      the sample procedure to start syntax checker
    
      The Syntax Checker will first do the parsing of the
      configuration file and then perform additional validation
      of the config file parms and provide additional
      information about the validation.
     For more information on syntax checker - see last release of
     QCF3.1 User's guide.
     For error messages from syntax checker - see last release of
     QCF3.1 User's guide.
    

Problem conclusion

Temporary fix

Comments

  • No comments
    

APAR Information

  • APAR number

    PK56487

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2007-11-13

  • Closed date

    2008-03-11

  • Last modified date

    2008-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK34444

Modules/Macros

  •    H0GN310J IQC##### IQCCCPRM IQCCIN0A IQCCIN0X
    IQCCIN08 IQCCIN09 IQCC1ENU IQCIMSII IQCP0000 IQCSINI0 IQCSIN10
    IQCSYNTX
    

Publications Referenced
SC18987500    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R310 PSY UK34444

       UP08/03/13 P F803

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date: