A fix is available
APAR status
Closed as program error.
Error description
Rational COBOL Runtime for zSeries V6.0.1: Abend 0C4 when generating and preparing an EGL generated COBOL program. The program's results file contains the following error: CCUE-022 The connection to the server was broken. Please ensure that the server is running and try the request again. The SYSOUT shows the following error: CEE3204S The system detected a protection exception (system completion code=0C4) from entry point readfine(char*,unsigned long*) at compile unit offset at address 00025148.
Local fix
Add REGION=0M in the JOB card for the CCUBLDW (build server) JOB. The following is an example of the build server JOB card with the REGION=0M added: 1 //AFUSXS1T JOB (,' '),'EGL BUILD JOB', // CLASS=M,MSGCLASS=Y,REGION=0M 2 //RUNPGM EXEC PGM=CCUBLDW,DYNAMNBR=30,TIME=NOLIMIT, // PARM='ENVAR("_CEE_ENVFILE=DD:EDCENV")/ // 1081 1193337564 1'
Problem summary
ABEND 0C4 when generating and preparing an EGL COBOL Program
Problem conclusion
See problem summary.
Temporary fix
Comments
APAR Information
APAR number
PK56042
Reported component name
RATL COBOL RT Z
Reported component ID
5655R2900
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-11-06
Closed date
2008-03-31
Last modified date
2008-08-29
APAR is sysrouted FROM one or more of the following:
PK56041
APAR is sysrouted TO one or more of the following:
UK35109
Modules/Macros
ELAUMAI
Fix information
Fixed component name
RATL COBOL RT Z
Fixed component ID
5655R2900
Applicable component levels
R601 PSY UK35109
UP08/04/12 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSN27B","label":"Rational COBOL Runtime for zSeries"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
29 August 2008