Error description
If the z/OS 1.9 ALLOWUSERKEYCSA parameter is set, or defaulted, to NO, ETO Support will ABEND with an SB78 RC=5C (ABENDSB78). This is because ETO Support allocated it's tables in E/CSA using a USER key.
Local fix
Set ALLOWUSERCSAKEY to YES.
Problem summary
**************************************************************** * USERS AFFECTED: All ETO Support users. * **************************************************************** * PROBLEM DESCRIPTION: If the z/OS ALLOWUSERKEYCSA parameter * * is set to NO, ETO Support will ABEND * * with an SB78 RC=5C (ABENDSB78). * **************************************************************** * RECOMMENDATION: * **************************************************************** If the z/OS ALLOWUSERKEYCSA parameter is set to, or defaulted to, NO, ETO Support will ABEND with an SB78 RC=5C (ABENDSB78). This is because ETO Support allocated it's tables in E/CSA using a USER key. A valid local fix would be to set ALLOWUSERCSAKEY to YES. (Which was the default prior to z/OS 1.9)
Problem conclusion
ETO Support has been changed to move its E/CSA tables from KEY 15 to KEY 7.
Temporary fix
Comments
APAR Information
APAR number
PK55770
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-31
Closed date
2007-11-16
Last modified date
2007-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK31375
Modules/Macros
IZTCSA01 IZTCSA02 IZTCSA03 IZTINTXZ
| SC18903602 |
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R310 PSY UK31375
UP07/11/20 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 December 2007