A fix is available
APAR status
Closed as program error.
Error description
Setting "Combine IX/TS Exceptions when evaluating IX triggering a TS" to "Y" in an Exceptions Profile can cause an ABEND0C4 in HAA$EXCP. It can also cause a LOOP HAA$EXCP (PK34100 level from offsets E63A to E718) when "Use Stats From" is set to "R"unstats. ****** ADDITIONAL SYMPTOMS ADDRESSED Currently the RUNSTATS utility options panel, HAA$URST, does not allow both the Report option and the 'Update Catalog Tables' to be set to 'N' to allow a RUNSTATS utility with REPORT=NO and UPDATE=NONE. This change will allow the RUNSTATS utility with REPORT=NO and UPDATE=NONE to be created in DB2 V8 and above.
Local fix
To eliminate the loop, specify something other than "R"unstats for "Use Stats From" field.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: Setting "Combine IX/TS Exceptions when * * evaluating IX triggering a TS" to "Y" * * in an Exceptions Profile can cause an * * ABEND0C4 in HAA$EXCP. It can also * * cause a LOOP HAA$EXCP (PK34100 level * * from offsets E63A to E718) when * * "Use Stats From" is set to "R"unstats. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK55068
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-19
Closed date
2007-12-20
Last modified date
2008-01-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK32561
Modules/Macros
HAA$BMSG HAA$EXCP HAA#ERSI HAA#UTOB HAA@PEXC HAA@PRSS HAAH0898 HAAH0899
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R220 PSY UK32561
UP07/12/28 P F712
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]