Error description

  • Setting up the parameters in ICAT for batch processing parameter
    001205 KDP_D2_STC                CID2H@@L
    001206 KDP_AUTODETECT_INTERVAL   300
    001207 KDP_STATUS_REFRESH        60
    .
    causes the following batch error
    PARAMETER           INPUT ERROR
    NAME                LINE# DESCRIPTION
    ------------------- -----
    
    KDP_D2_STC          1205  Invalid Parameter Sequence: Product
                              Parameter does not belong to this
                              Product Begin/End-Block.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. The parameters for configuring the   *
    *                      Server started task that the Agent      *
    *                      should connect to, are always commented *
    *                      out in the generated parameter deck for *
    *                      batch mode install. When the comments   *
    *                      are removed ICAT batch mode install     *
    *                      causes the following error:             *
    *                      Invalid parameter sequence: Product     *
    *                      Parameter does not belong to this       *
    *                      Begin/End-Block.                        *
    *                                                              *
    *                      2. The allocation of additional runtime *
    *                      datasets fails when the log and output  *
    *                      datasets for Automatic Exception        *
    *                      Processing are not specified for all    *
    *                      DB2 subsystems.                         *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    1. ICAT batch mode install causes the following error:
    Invalid parameter sequence: Product Parameter does not belong to
    this Begin/End-Block.
    2. Allocation of runtime datasets fails.
    
    PROBLEM CONCLUSION:
    1. In case the parameters are set during ICAT configuration the
    parameters will be made available for batch mode install. If the
    parameters are not set the parameters will be commented out.
    The parameters fullfil the naming conventions now and therefore
    batch mode install runs successfully.
    2. The enabling flags for the log and output datasets are
    evaluated correctly.
    

Problem conclusion

  • 1. In case the parameters are set during ICAT configuration the
    parameters will be made available for batch mode install. If the
    parameters are not set the parameters will be commented out.
    The parameters fullfil the naming conventions now and therefore
    batch mode install runs successfully.
    2. The enabling flags for the log and output datasets are
    evaluated correctly.
    
    
    KEYWORDS :BATCH MODE INSTALL INVALID PARAMETER SEQUENCE AGENT
    ALLOCATION AUTO EXCEPTION PROCESSING DATASETS CANCEL THREAD
    PRIVILEGES
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK54975

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-10-18

  • Closed date

    2007-10-23

  • Last modified date

    2007-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK30524 UK30525

Modules/Macros

  •    KD260CVA KD260SS3 KD261CVA KD261PY  KD5BHELP
    KD5DDICT KD5SBATO KD531HUB KD531HUC KD531HUD KD531MCU KD5310SP
    KD5410SP
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK30524

       UP07/10/30 P F710

  • R410 PSY UK30525

       UP07/10/30 P F710

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]

Document Information

Modified date:
31 March 2021