IBM Support

PK50542: HPIC TERMINATES WITH ABEND S0C1 ( ABEND 0C1 ) AT OFFSET FABJTOI + X'656' AFTER PK41921/UK23667 07/08/07 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After applying APAR PK41921, HPIC terminates with ABEND S0C1 (
    ABEND0C1 ) in FABJTOI + X'656' when TOSI=O is specified.
    

Local fix

  • No Work Around
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR is the fix for APAR PK31006   *
    *                      and PK41921.                            *
    *                      After applying APAR PK31006, TOIAUTO=O  *
    *                      process of HPIC V4R1 Image Copy         *
    *                      function terminates with ABEND S0C2     *
    *                      ( ABEND0C2 ).                           *
    *                      After applying APAR PK41921, TOIAUTO=O  *
    *                      process of HPIC V4R1 Image Copy         *
    *                      function terminates with ABEND S0C1     *
    *                      ( ABEND0C1 ).                           *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR is the fix for APAR PK31006 and PK41921.
    HPIC V4R1 Image Copy function terminates with ABEND S0C1
    ( ABEND0C1 ) or ABEND S0C2 ( ABEND0C2 ), when TOIAUTO=O is
    specified in the ICEIN control statement.
    TOIAUTO=O is required APF authorization, but authorization check
    routine is not processed by APAR PK31006.
    
    The cause of S0C2 ( ABEND0C2 ) is that HPIC tries to change into
    the supervisor mode without an APF authorization after applying
    APAR PK31006.
    The cause of S0C1 ( ABEND0C1 ) is that HPIC calls FABDAI00 that
    is not loaded after applying APAR PK41921.
    

Problem conclusion

  • FABJMAIN has been modified to load the FABDAI00 and to check
    an APF status, when TOIAUTO=O is specified in the ICEIN control
    statement.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK50542

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-08-07

  • Closed date

    2007-08-10

  • Last modified date

    2007-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK28106

Modules/Macros

  • FABJMAIN
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK28106

       UP07/08/14 P F708 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: