Error description

  • Map runs successfully using WTX 8.0.1.
    
    When using 8.0.1.1 or WTX 8.1 the map fails with 'Input valid
    but unknown data found'.
    
    Issue was replicated.
    

Local fix

  • WTXCQ00001488
    GK
    No Workaround available.
    

Problem summary

  • Information about the current position in the data was not being
    saved at the right point in the processing.  As a result, when
    the component rule on a group failed, not all of the information
    about the group was removed from the work file, and validation
    did not resume at the right point in the data.
    

Problem conclusion

  • Information about the current position in the data was not being
    saved at the right point in the processing.  As a result, when
    the component rule on a group failed, not all of the information
    about the group was removed from the work file, and validation
    did not resume at the right point in the data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK50277

  • Reported component name

    WEBSPHERE LAUNC

  • Reported component ID

    5724M4011

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-08-02

  • Closed date

    2008-02-01

  • Last modified date

    2008-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE LAUNC

  • Fixed component ID

    5724M4011

Applicable component levels

  • R751 PSY

       UP

  • R800 PSY

       UP

  • R801 PSY

       UP

  • R810 PSY

       UP

  • R820 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
01 February 2008