IBM Support

PK49835: REBIND STATEMENTS FROM EARLIER WSL RUN REISSUED, ADBHOLD TABLE MANAGEMENT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The DB2 Administration Tool WSL execution stored commands which
    resulted in an error in the ADBHOLD table and reissues the
    commands when the WSL is restarted. This can result in
    unexpected REBIND statements being issued when the WSL name is
    used again.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Administration Tool using the   *
    *                 the ADBTEP2 Batch Restart Utilityprogram.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: DBTEP2 restart processing processes     *
    *                      unrelated ADBHOLD statements.           *
    ****************************************************************
    * RECOMMENDATION: Apply The PTF.                               *
    ****************************************************************
    ADBTEP2 incorrectly  processes all rows of the ADBHOLD table
    instead of just those rows that match the current checkpoint
    record.
    

Problem conclusion

  • The problem has been fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK49835

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-26

  • Closed date

    2007-12-07

  • Last modified date

    2008-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ADBTEP2
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • R710 PSY UK32063

       UP07/12/19 P F712

  • R720 PSY UK32064

       UP07/12/19 P F712

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 January 2008