A fix is available
APAR status
Closed as program error.
Error description
FABY2004E REASON=91B00000 and FABY2005E REASON=919000 received.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Prefix Resolution * * for z/OS Version 3 Release 1 users * * (FMID=H1IP310). * **************************************************************** * PROBLEM DESCRIPTION: When TYPE=LM or TYPE=IM is specified * * and WF1 file is very large, * * MSGFABY2004E is issued. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the prefix resolution function is run with TYPE=IM or TYPE=LM and WF1 file is very large, MSGFABY2004E TIME-OUT IN READER OF PIPE FABYPIPE.#01 is recieved. When a subtask task to read or write data by the use of HPPRPIPE remains in a wait state and the wait time exceeds 15 minutes, the task results in a timeout.
Problem conclusion
The wait time has been extended to 24 hours so that a reader task or a writer task avoids a timeout that occurs in a short time.
Temporary fix
Comments
APAR Information
APAR number
PK49334
Reported component name
IMSPREFIXRESOLU
Reported component ID
5655I1500
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-07-19
Closed date
2007-08-01
Last modified date
2007-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK27677
Modules/Macros
FABYPI00
Fix information
Fixed component name
IMSPREFIXRESOLU
Fixed component ID
5655I1500
Applicable component levels
R310 PSY UK27677
UP07/08/02 P F708
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89H","label":"IMS HP Prefix Resolution"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date: