A fix is available
APAR status
Closed as program error.
Error description
1.) Issuing the command /F O2CI,F EVENTMGR,STOP DB2=<ssid> causes a 0C1/RC1 during Object Analysis shutdown. Furthermore Object Analysis is shut down for ALL subsystems on the LPAR that are configured to use Object Analysis 2.) In certain situations not all Object Analysis instances are started when configured using the autostart option.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON Server * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C1 in Event Manager (EVENTMGR) * * module O2ECTL caused by the following * * Modify Stop Command: * * F o2ci,F EVENTMGR,STOP DB2=ssid * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Event Manager was calling an invalid STOP routine entry address. PROBLEM CONCLUSION: Event Manager code has been changed to reference the correct STOP routine entry address.
Problem conclusion
Event Manager code has been changed to reference the correct STOP routine entry address. KEYWORDS : EVENT MANAGER ABEND0C1 O2ECTL STOP ROUTINE
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK48971
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2007-07-16
Closed date
2008-04-07
Last modified date
2008-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK35315
Modules/Macros
KO2ECTLC KO2ECTLF
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R310 PSY UK35315
UP08/04/09 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: