A fix is available
APAR status
Closed as program error.
Error description
Intermittently, USRCPUT for long-running tasks is non-sensical. It is either too large. Or it suddenly jumps from large to smaller. This can happen in an environment where Performance Class monitoring is on most of the time but is turned off and back on occasionally. If an EXEC CICS MONITOR command is issued while Performance Class monitoring is temporarily off, the problem will happen. (TCPIP/CICS Sockets interface code is one product that does EXEC CICS MONITOR commands.)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: When a long running transaction is * * executing and performance monitoring * * has been switched off and on, USRCPUT * * monitor field may be an incorrect * * value. * **************************************************************** * RECOMMENDATION: * **************************************************************** If a long running transaction is executing and performance monitoring is active, if this is then turned off and the transaction then issues an EXEC CICS MONITOR POINT, the cpu time interval may contain an invalid value. If performance monitoring is turned on again this invalid value will appear in the monitoring record for this transaction. Keywords: QRCPUT DFHTASK ROCPUT J8CPUT J9CPUT L8CPUT L9CPUT S8CPUT X8CPUT X9CPUT KY9CPUT KY8CPUT 256 259 260 261 263 265 267 270 271 272
Problem conclusion
DFHMNMN has been changed in read_cpu_time to clear cpu_time_interval when cpu timing is not active.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK48270
Reported component name
CICSTS V3 Z/OS
Reported component ID
5655M1500
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-07-03
Closed date
2007-08-20
Last modified date
2007-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK28331
Modules/Macros
DFHMNMN
Fix information
Fixed component name
CICSTS V3 Z/OS
Fixed component ID
5655M1500
Applicable component levels
R500 PSY UK28331
UP07/08/24 P F708
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]