A fix is available
APAR status
-
Closed as program error.
Error description
-
HD Pointer Checker causes abend 0C4 when - run under IMS Parallel Reorganization with Index Builder - database has logical relationship to other database - database has secondary index - INDEXBLD=YES and ICTYPE=A.
Local fix
-
No work around
Problem summary
-
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 2 Release 2 (FMID=HPC2220) * * users who run HD pointer checker * * under IMS Parallel Reorganization for * * z/OS Version 3 Release 2 (FMID=H25N320). * **************************************************************** * PROBLEM DESCRIPTION: HD Pointer Checker (HDPC) gets ABEND0C4 * * in FABPHEXS CSECT in load module * * FABPHEXS. The data at PSW contains * * X'9180 507A' ( TM X'7A'(R5),X'80' ). * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The ABEND0C4 may occur when all of the following conditions are satisfied: - The HD Pointer Checker (HDPC) is called by the IMS Parallel Reorganization (IPR) V3R2. - The database reorganized by IPR has a logical relationship with another database. - The database reorganized by IPR is indexed by secondary index. - Both INDEXBLD=YES and ICTYPE=A are specified in the HPSIN statement of IPR, HDPC erroneously refers to an internal control block for the logically related database, although the control block is not built because such a database is not checked by HDPC.
Problem conclusion
-
The module FABPHEXS has been fixed not to refer the control block which is not built.
Temporary fix
Comments
APAR Information
-
APAR number
PK46765
-
Reported component name
IMS POINTER CHE
-
Reported component ID
5655E0900
-
Reported release
220
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2007-06-08
-
Closed date
2007-06-15
-
Last modified date
2007-07-03
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK26119
Modules/Macros
-
FABPHEXS
Fix information
-
Fixed component name
IMS POINTER CHE
-
Fixed component ID
5655E0900
Applicable component levels
-
R220 PSY UK26119
UP07/06/16 P F706
Fix is available
-