A fix is available
APAR status
Closed as program error.
Error description
INVALID ADDRESSING MODE BIT SET BY OBJECT ANALYSIS CAUSES MEDIA MANAGER TO ABNORMALLY TERMINATE WITH ABEND0C4 / ABEND0C1 Invalid addressing mode bit set by Object Analysis causes Media Manager to abnormally terminate with ABEND0C4 / ABEND0C1 The AMODE problem is caused by a series of LLGTR instructions (load logical thirty one bits) at the beginning of the OMEGAMON At the point in time of the S0C4, R14=010FDEFA and the PSW at time of error is 070C3000 000FDEFA. R14 is used within a BSM instruction and therefore switches the AMODE of the PSW to AMODE24 thus causing the S0C4. R12 at the point in time of the S0C4 ABEND points to the entry point of DSNB5UTX (R12=1CEDC5C8) and therefore the critical BSM instruction is executed out of DSNB5UTX. DSNB5UTX is at maintenance level UQ75848 (DSNB5UTX 04/09/03 UQ75848) and DSNB5UTX contains a return instruction via PSARET (PSA+37A, PSARET points to a BSM R0,R14). Modules hit: KO2EOJSA and KO2EIX12, KO2EIX1S, KO2EIX1A
Local fix
Turn off Object Analysis untill an APAR fix is available.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON Server * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C1 OR ABEND0C4 IN DB2 MODULE * * DSNB5UTX ON RETURN TO MEDIA MANAGER * * IN 24-BIT ADDRESSING MODE. * **************************************************************** * RECOMMENDATION: APPLY THIS PTF * **************************************************************** ABEND0C1 OR ABEND0C4 FAILURE WHEN DSNB5UTX ENTERED BY OMEGAMON XE FOR DB2 PE MODULE O2EIX1, EXITS TO MEDIA MANAGER IN 24-BIT ADDRESSING MODE.
Problem conclusion
CHANGED MODULE O2EIX1 TO PRESERVE THE MEDIA MANAGER ADDRESSING MODE ON ENTRY AND RESTORE ADDRESSING MODE ON EXIT BEFORE CALLING DSNB5UTX ENTRY POINT. KEYWORDS : ABEND0C1 ABEND0C4 ICYEXIT DSNB5UTX O2EIX1 OBJECT ANALYSIS
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK46357
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-06-01
Closed date
2007-06-19
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK26248 UK26247 OA22867
Modules/Macros
KO2EGX1A KO2EGX1T KO2EGX1W KO2EGX13 KO2EIX1A KO2EIX1T KO2EIX1W KO2EIX13
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: