IBM Support

PK46091: EXCEPTION IDBC IS NOT WORKING CORRECTLY. IN-DB2 CPU TIME IS NOT CORRECTLY CALCULATED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IN-DB2 time is not correctly calculated when using IDBC alert.
    Customer states that the internal calculation is using a value
    for In-DB2 cpu that is sometimes double the actual cpu. This
    triggers off the Alert incorrectly.  This is being seen on
    DB2 V8.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 - Classic Interface                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXCEPTION IDBC IS NOT WORKING           *
    *                      CORRECTLY. IN-DB2 CPU TIME IS NOT       *
    *                      CORRECTLY CALCULATED.                   *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROCESSING EXCEPCION IDBC OM/DB2 CALCULATES ACCUMULATED
    TCB TIME IN DB2 INCORRECTLY.
    

Problem conclusion

  • PROGRAM HAS BEEN TO PROCESS ACCUMULATED
    TCB TIME IN DB2 CORRECTLY.
    
    KEYWORDS: INCORROUT EXCEPCION IDBC IN-DB2 CPU TIME
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK46091

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-05-30

  • Closed date

    2007-09-20

  • Last modified date

    2007-10-02

  • APAR is sysrouted FROM one or more of the following:

    OA20740

  • APAR is sysrouted TO one or more of the following:

    UK29350 UK29355

Modules/Macros

  •    KO2CTHIS KO2CTHI2 KO2CTH3A KO2CTH3S KO2CTH32
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK29350

       UP07/09/21 P F709

  • R410 PSY UK29355

       UP07/09/21 P F709

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: