Error description

  • There is a discrepancy between the calculation of ADDBCPUT of
    Accounting Trace report and CLASS2_CPU_TOTAL from the
    performance database table DB2PMFACCT_GENERAL. The value of
    QWACCLS2_ZIIP should not be added to ADDBCPUT when preparing
    CLASS2_CPU_TOTAL.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Batch Reporting                          *
    *                 -   Performance Database users               *
    ****************************************************************
    * PROBLEM DESCRIPTION: CLASS 2 IIP CPU TIME from QWACCLS2_ZIIP *
    *                      field is added to CLASS2_CPU_TOTAL.     *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    QWACCLS2_ZIIP has incorrectly been added to CLASS2_CPU_TOTAL
    when creating FILE data. This is a discrepancy to Accounting
    Report and Trace.
    

Problem conclusion

  • The code has been changed. CLASS2_CPU_TOTAL will show a sum
    without QWACCLS2_ZIIP.
    
    KEYWORDS : CLASS2_CPU_TOTAL QWACCLS2_ZIIP ADDBCPUT PERFORMANCE
    DATABASE DB2PMFACCT_GENERAL ACCOUNTING FILE
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK44432

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-05-03

  • Closed date

    2007-05-09

  • Last modified date

    2007-06-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    DUMM2KO2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSN UK24809

       UP07/05/11 P F705

  • R410 PSN UK24829

       UP07/05/11 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]