IBM Support

PK43750: BPL MISSING TRACE RECORDS CAUSED BY HIGH GTF TRACE VOLUME

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGBPL542E is received for missing records from GTF trace as
    a result of high GTF trace volume.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: ALL IMS BUFFER POOL ANALYZER USERS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: TRACE REPORT RECEIVES MESSAGE BPL542E   *
    *                      WHEN VOLUME OF GTFTRACE DATA IS VERY    *
    *                      HIGH.                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    TRACE REPORT RECEIVES MESSAGE BPL542E WHEN VOLUME OF
    GTFTRACE DATA IS VERY HIGH.
    ABEND0C4 WHEN MORE THAN 388 DBD= STATEMENTS ARE PRESENT
    IN DFSVSAMP DD INPUT TO THE BPA REPORT JOB.
    UPDATE MESSAGE BPL613I TO PROVIDE IMPROVED DESCRIPTION
    OF THE IMPACT OF LOST TRACE RECORDS.
    

Problem conclusion

  • UPDATE SAMPLE GTF TRACE PROC TO ALLOW OVERRIDES TO ECSA
    SPACE, BUFFER SPACE, AND CONCURRENT I/O'S USED BY THE
    GTF TRACE PROCESS.
    CORRECT ERROR WHEN DBD= STATEMENTS SPAN TO A SECOND IPAGE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK43750

  • Reported component name

    IMS BUFFER POOL

  • Reported component ID

    5697H7700

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-04-20

  • Closed date

    2007-05-14

  • Last modified date

    2007-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK25096

Modules/Macros

  •    BPLGTF   BPLMAIN  BPLTRACE BPLTRRP1
    

Publications Referenced
SC18706801    

Fix information

  • Fixed component name

    IMS BUFFER POOL

  • Fixed component ID

    5697H7700

Applicable component levels

  • R110 PSY UK25096

       UP07/05/16 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY3","label":"IMS Buffer Pool Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]

Document Information

Modified date:
14 December 2020