A fix is available
APAR status
Closed as program error.
Error description
When FASTIC=(PREF,DUMP) is specified, and the maximum number of concurrent sessions reaches it's maximum, HP Image Copy continues to process by direct Data Base Data Set access (normal image copy). But HPIC does not register the output IC data set into DBRC and terminates the process with RC=08. HPIC will now register the IC with DBRC, and complete with RC=0 for this situation.
Local fix
no work around
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: When connection section of the * * concurrent copy is over the limit * * number, HPIC V4R1 Image Copy Function * * with FASTIC=(PREF,DUMP) continues to * * create image copy data set but the IC * * record in DBRC is not registered and * * the process terminates with RC=8. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When connection section of the concurrent copy is over the limit number, HPIC V4R1 Image Copy Function with FASTIC=(PREF,DUMP) continues to create image copy data set but the IC record in DBRC is not registered and the process terminates with RC=8. When the FASTIC=(PREF,DUMP) is requested and the number of concurrent copy session reaches to maximum, the logical copy of concurrent copy phase fails but the physical copy phase continues to create image copy data set. But HPIC checks the return code from DFSMSdss at logical copy phase and regards the process as error.
Problem conclusion
FABJDFCN has been modified to check whether DFSMSdss physical copy process has completed or not. If physical copy has completed, HPIC considers that the Image Copy process has ended normally, even though return code of DFSMSdss is not zero. FABJFCDN has been modified to register Image Copy record into DBRC, when DFSMSdss physical copy has completed. The following modules have been reassembled: FABJDFC7, FABJDFC8, FABJDFC9, FABJDFCA, FABJFCD7, FABJFCD8, FABJFCD9, FABJFCDA ======================== = DOCUMENTATION CHANGE = ======================== IMS High Performance Image Copy for z/OS Version 4 Release 1 User's Guide SC18-9409 ( SC189409 ) should be changed as follows: A.0 Appendix A. Return Codes, Abend Codes, and Messages A.3 Messages The message FABJ4241I is added. | FABJ4241I PHYSICAL COPY PROCESS WILL BE CONTINUED BECAUSE | FASTIC=(PREF,DUMP) IS SPECIFIED. | | Explanation: Message ADR735W has issued and DFSMSdss logical | copy process has failed, but the physical copy process will be | continued. Because FASTIC=(PREF,DUMP) is specified in ICEIN | statement. | | System Action: Continue the process. | | Programmer Response: None.
Temporary fix
Comments
APAR Information
APAR number
PK43716
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-04-20
Closed date
2007-04-26
Last modified date
2007-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK24442
Modules/Macros
FABJDFCA FABJDFCN FABJDFC7 FABJDFC8 FABJDFC9 FABJFCDA FABJFCDN FABJFCD7 FABJFCD8 FABJFCD9
| SC18940900 |
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK24442
UP07/04/28 P F704
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.