Error description

  • ABEND0C4 IN KO2EGX13/KO2EGX1
    
    FYI.
    
    SEARCH ARGUMENT ABSTRACT
    
      RIDS/KO2EGX13#L RIDS/KO2EGX1 AB/S00C4 PRCS/00000010 REGS/0F17A
    REGS/C08EE
      RIDS/FRREGX1#R
    
      Symptom             Description
      -------             -----------
      RIDS/KO2EGX13#L     Load module name: KO2EGX13
      RIDS/KO2EGX1        Csect name: KO2EGX1
      AB/S00C4            System abend code: 00C4
      PRCS/00000010       Abend reason code: 00000010
      REGS/0F17A          Register/PSW difference for R0F: 17A
      REGS/C08EE          Register/PSW difference for R0C:-08EE
      RIDS/FRREGX1#R      Recovery routine csect name: FRREGX1
    
    Time of Error Information
    
      PSW: 07042000 80000000 00000000 25657A0A
      Instruction length: 06   Interrupt code: 0010
      Failing instruction text: F4684740 F47CD502 4004F528
      Translation exception address: 00000000_40404000
    
      Breaking event address: 00000000_256579BA
      AR/GR 0-1    00000000/00000000_25658610
    00000000/00000000_78408C81
      AR/GR 2-3    00000000/00000000_00000013
    00000000/00000005_777EFD68
      AR/GR 4-5    00000000/00000005_40404040
    00000000/00000005_00001F3C
      AR/GR 6-7    00000000/00000000_1E9562C0
    00000000/00000000_00000000
      AR/GR 8-9    00000000/00000000_78408C66
    00000000/00000000_00000018
      AR/GR 10-11  00000000/00000005_00000C40
    00000000/00000000_256584A0
      AR/GR 12-13  00000000/00000000_256582F8
    00000000/00000000_784088D0
      AR/GR 14-15  00000000/00000000_2CF7FD92
    00000000/00000000_25657890
    
    CPU STATUS:
    PSW=070C2000 A5657A0A
        (Running in PRIMARY, key 0, AMODE 31, DAT ON)
        DISABLED FOR PER
    Unable to identify the area at ASID(X'0244') address 25657A0A.
      ASCB77 at F60F00, JOB(PAJ0DIST), for the home ASID
      ASXB77 at 7FDD00 for the home ASID. No block is dispatched
      HOME ASID: 004D PRIMARY ASID: 0244 SECONDARY ASID: 0244
    
      General purpose register values
         0-1  00000000_25658610  00000000_78408C81
         2-3  00000000_00000013  00000005_777EFD68
         4-5  00000005_40404040  00000005_00001F3C
         6-7  00000000_1E9562C0  00000000_00000000
         8-9  00000000_78408C66  00000000_00000018
        10-11 00000005_00000C40  00000000_256584A0
        12-13 00000000_256582F8  00000000_784088D0
        14-15 00000000_2CF7FD92  00000000_25657890
    
    256577F0
    | ...........  *** |
    |  COPYRIGHT (C) 1 |
    | 977,1988 - 2002  |
    | CANDLE CORPORATI |
    | ON *** .O2EGX1   |
    |  V54051008/03/06 |
    |  12:00.{UA28095  |
    | DB2810  MVS610   |
    | COPYRIGHT (C) CA |
    | NDLE CORPORATION |
    
    FYI.
    
    The code is abending on a compare CLC, using R4 as one of the
    base registers.
    
    From the symptoms, we have r4 containing blanks: x'40404040'.
    R4 is loaded after some bit twiddling/shifting which looks very
    questionable.  We are picking up a page number BBPAGE which
    looks like a EYECATCHER, rather than some hex number.  The
    buffer block is pointed to by register 1: 78408C81.  The entire
    code area is standing on very shaky ground.
    
    Our interpretation of the BB (Buffer Block) control block needs
    an update.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 IN KO2EGX13/KO2EGX1            *
    ****************************************************************
    * RECOMMENDATION: APPLY THIS PTF                               *
    ****************************************************************
    OM/DB2 TRIES TO GET DATA FROM DB2 CONTROL BLOCK BUT STORAGE IS
    ALREADY UNAVAILABLE TO READ.
    

Problem conclusion

  • PROGRAM HAS BEEN CHANGED TO VERIFY THE STATUS OF DB2 STORAGE
    BEFORE READ.
    
    KEYWORDS : ABEND0C4 EGX1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK43706

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-04-23

  • Closed date

    2007-05-07

  • Last modified date

    2007-06-04

  • APAR is sysrouted FROM one or more of the following:

    OA20089

  • APAR is sysrouted TO one or more of the following:

    022PC5Ÿ UK24797 022PC5Ÿ UK24798 022PC5Ÿ

Modules/Macros

  •    KO2EGX1A KO2EGX1T KO2EGX1W KO2EGX13
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK24797

       UP07/05/09 P F705

  • R410 PSY UK24798

       UP07/05/09 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]