APAR status
Closed as program error.
Error description
When FPB Unload runs under the following conditions, it abends with ABENDS0C4 and ABENDU3700 with MSGFABC3700E. The ABEND0C4 is out of FABCUR1U at x'446'. This occurs when "change mode" is used to change the randomizing module and when the area number defined in the OLDACB library is greater than the one in the NEWACB library. Additional Keywords: FABC3700E S0C4 U3700 This is a forward fit of HPFPU V2R2 HPFP FPB APAR PK41436
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All DEDB Unload/Reload users of High * * Performance Fast Path Utilities FP Basic * * Tools Version 3 Release 1 (FMID: H31A310). * **************************************************************** * PROBLEM DESCRIPTION: FABCUR1 gets S0C4 and U3700 abend with * * FABC3700E message while * * "change randomizer module mode" * * unloading with RMODTYPE=S option. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Forward Fit APAR of HPFPU V2R2 PK41436. FABCUR1 gets S0C4 and U3700 abend with FABC3700E message while "change randomizer module mode" unloading with RMODTYPE=S option.
Problem conclusion
Forward Fit APAR of HPFPU V2R2 PK41436. 1. FABCUR1 calls a new randomizer defined in the NEWACB library when "change randomizer module mode" unloading. In this trouble case, the number of areas defined in the OLDACB library greater than the one in the NEWACB library. Setting the interface parameters for the user exit as an common process regardless of calling user exit routine, FABCUR1 points at out of the internal table of the area number defined in the OLDACB library because the number is greater than the largest area number defined in the NEWACB, and then gets S0C4 abend. FABCUR1 has modified to set the user exit interface area information parameters after calling the randomizer if randomizer must be called. 2. FABCUR1 issues a new message FABC0185I once per area when a new randomizer randomizes a record to another area that is different from the original one while unloading with RMODTYPE=S option. ======================== = DOCUMENTATION CHANGE = ======================== The IMS High Performance Fast Path Utilities for z/OS User's Guide Volume 2: Fast Path Basic Tools Version 3 Release 1 (SC18-9870-00) should be updated as follows: Appendix O. FPB.Messages and codes FABC messages The following message should be added as follows: | FABC0185I - RMODTYPE=S BUT RANDOMIZED TO ANOTHER AREA | | Explanation: RMODTYPE=S is specified, but the randomizer | randomized a record to another area that is different from | the original one. | System Action: FABCUR1 continues processing. | Programmer Response: None 310Y FABCUR1U FABC1INI UR#DUCT0
Temporary fix
Comments
×**** PE08/05/20 PTF IN ERROR. SEE APAR PK66252 FOR DESCRIPTION
APAR Information
APAR number
PK42190
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-03-28
Closed date
2007-04-04
Last modified date
2008-05-21
APAR is sysrouted FROM one or more of the following:
PK41436
APAR is sysrouted TO one or more of the following:
UK23743
Modules/Macros
FABCUR1U FABC1INI UR#DUCT0
| SC18987000 |
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R310 PSY UK23743
UP07/04/06 P F704
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: