APAR status
Closed as program error.
Error description
Reproduced with PowerBuilder 9 and Robot 7.0 If a combobox contains an item with the string Test1
Local fix
Problem summary
Problem : Forward-slash in text of a PowerBuilder combobox item splits the item into multiple rows for verification points Solution : '/' character is the delimiter for the for powerbuilder data. We replace this character with a new line ( '\n' and '\r' ) before sending it to the comparator. Here in this case the data itself is having the Forward-slash character in it and when we parse it the same will be treated as a delimiter. Added logic to skip if '/' found as part of the data
Problem conclusion
Fixed the issue and now Robot will be able to pick '/' character that comes as part of the Powerbuilder Data
Temporary fix
Comments
APAR Information
APAR number
PK42018
Reported component name
RATIONAL ROBOT
Reported component ID
5724G2400
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-03-26
Closed date
2008-06-25
Last modified date
2008-06-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATIONAL ROBOT
Fixed component ID
5724G2400
Applicable component levels
R700 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHDX","label":"Rational Robot"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
25 June 2008