A fix is available
APAR status
Closed as program error.
Error description
The data type of OCC column that is generated for Oracle 10 is m issing if a top-down EJB to RDB mapping is used.
Local fix
Manually set OCC column type to NUMBER(19,0)
Problem summary
**************************************************************** * USERS AFFECTED: All users creating a top-down Oracle * * backend mapping for Container Managed * * Persistence Enterprise JavaBeans. * **************************************************************** * PROBLEM DESCRIPTION: The OCC column generated for top-down * * Oracle backends is missing a data type. * **************************************************************** * RECOMMENDATION: * **************************************************************** When creating an Oracle backend for CMP EJBs where an OCC column is needed, the generated OCC column in the Database metadata is missing a data type
Problem conclusion
The generated Oracle Database backend metadata will now map the OCC column to a NUMBER(19,0) data type. The fix for this APAR is currently targeted for inclusion in Rational Application Developer v7.0.0.4 and WebSphere Application Server Toolkit v6.1.1.4. Please refer to the Recommended Updates page for WebSphere Application Server Toolkit fixpack delivery information: http://www.ibm.com/support/docview.wss?uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PK41548
Reported component name
WEBAPP SERVER A
Reported component ID
5724J0820
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-03-21
Closed date
2007-04-19
Last modified date
2007-07-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBAPP SERVER A
Fixed component ID
5724J0820
Applicable component levels
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: