PK36720: ABEND U0083 WHEN FPA CHANGE FUNCTION PROCESSES 24 AREAS IN PARALLEL.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend U0083 when FPA change function processes 24 areas in
    parallel.  FPA couldn't dynamically allocate SORT WORK data
    sets for the internal sorting.
    Aditional Keywords:
    ABENDU0083
    

Local fix

  • Process less than 24 areas at a time.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Fast Path Advanced Tool         *
    *                 Version 3 Release 1. (FMID: H31A310)         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. ABENDU0083 occurs when FPA change    *
    *                        function processes a large number of  *
    *                        areas in parallel.                    *
    *                      2. The error message HFPI0005E is not   *
    *                        clear when the PTF level of the HPIC  *
    *                        is not high enough.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1. FPA calls DFSORT internally to sort some kinds of records.
      DFSORT allocates the sort work data sets dynamically for an
      area according to the installation defaults of DFSORT because
      FPA does not pass the number of work data sets to DFOSRT.
      Therefore, if large number is defined as the number of work
      data sets in the installation defaults, ABENDU0083 can occur
      with the following FPA functions.
     - ANALYZE with PTRCHKLVL=FULL keyword using multiple tasks
     - CHANGE in non-REORG mode (restructure) with multiple tasks
     - EXTRACT with SORT=YES keyword using multiple tasks
     - RELOAD with SORT=YES keyword using multiple tasks
     - UNLOAD with SORT=YES keyword using multiple tasks
    2. FPA issues the following message during the image copy
      creation process if the PTF level of the HPIC is not high
      enough.
        HFPI0005E AN ERROR WAS DETECTED IN THE HPIC PROCESSING FOR
                   RELOAD.
         - FUNCTION: INIT1, RETURN CODE:  8, REASON CODE: 00020001.
      Because the message is not clear, it should be changed.
    

Problem conclusion

  • 1. FPA is changed to pass '3' as the number of work data sets
      to DFSORT.
    2. FPA is changed to issue new sub text of HFPI0006E if the
      PTF level of the HPIC is not high enough.
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS High Performance Fast Path Utilities for z/OS User's
    Guide Volume 1: Fast Path Advanced Tools Version 3 Release 1
    (SC18-9869-00) should be added and changed as follows:
    Appendix H. Message and Codes
      HFPI messages
    HFPI0006E IMAGE COPY OUTPUT PROCESSING FAILED.
            - THE PTF LEVEL OF THE HPIC MODULE IS NOT HIGH ENOUGH.
    310Y
    HFPAST40
    HFPA3S00
    HFPA3000
    HFPA4000
    HFPIICE0
    HFPTSRI
    HFPTSRT0
    HFPWMTI0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK36720

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-12-28

  • Closed date

    2007-01-14

  • Last modified date

    2007-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK21250

Modules/Macros

  •    HFPAST40 HFPA3S00 HFPA3000 HFPA4000 HFPIICE0
    HFPTSRI  HFPTSRT0 HFPWMTI0
    

Publications Referenced
SC18986900    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R310 PSY UK21250

       UP07/01/16 P F701