A fix is available
APAR status
Closed as program error.
Error description
When display of DB2 Connect / Gateway, and look in Statistics, the 'Time Zone Displacement' field shows " -5:00:00" and the 'Gateway Snapshot Time' shows " 12/31/99 7:00:00 PM". The Time Zone Displacement is incorrect and the Snapshot Time is incorrect and does not change. The Gateway Snapshot Time field may show dates of 20th Century or other incorrect dates when the host server runs in the WesternHemisphere time zone.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON Server * **************************************************************** * PROBLEM DESCRIPTION: The Gateway Snapshot Time field may * * show dates of 20th century or other * * incorrect dates when the Host Server * * is running in Western hemisphere * * time zones. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. When the Host Server is running in Western hemisphere time zones, PE Client shows incorrect time and date of 1997 or 1999 year in the Gateway Snapshot Time field. 2. When the Host Server is running in Eastern hemisphere time zone, PWH is not running at the moments when Daylight Saving Time starts or ends PE Client shows Gateway Snapshot Time with + /- 1 hour error until PWH gets started.
Problem conclusion
1. A time difference is now added to the gateway timestamp if time zone displacement is negative. 2. Omegamon Server checks Daylight Saving Time starts and ends each midnight and corrects DB2PM.VERSION table with correct time difference in seconds. ---------------------------------------------------- KEYWORDS: GATEWAY SNAPSHOT TIME, EESGD004, TIME DIFFERENCE, TIME ZONE DISPLACEMENT, DB2 CONNECT
Temporary fix
Comments
APAR Information
APAR number
PK36063
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-12-11
Closed date
2007-01-03
Last modified date
2007-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK20997 PK37652 PK37709
Modules/Macros
DGO@SDOB DGOVSCNI DGOVSCS2 DGOVSDOB DGOVSDSC
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R310 PSY UK20997
UP07/01/12 P F701
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]