Error description

  • After applying PK32595, IPR Scan utility receives ABENDS0C4-11
    at FABH002+X'008A'.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS High Performance Unload for *
    *                 OS/390 Release 1 (FMID=H1IN110), and IPR DB  *
    *                 Scan Utility of IMS Parallel Reorganization  *
    *                 for z/OS Version 3 Release 1 (FMID=H25N310)  *
    *                 and Version 3 Release 2 (FMID=H25N320)       *
    ****************************************************************
    * PROBLEM DESCRIPTION: The following problems occur after      *
    *                      applying APAR PK32595:                  *
    *                      1) IPR Scan utility receives            *
    *                         ABENDS0C4-11 at FABH002+X'008A'.     *
    *                      2) HP Unload API returns the GE status  *
    *                         code erroneously in the GNP/GHNP     *
    *                         call with two SSAs in APISET 2 or 3. *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The following problems occur after applying APAR PK32595:
    1) IPR Scan utility receives ABENDS0C4-11 at FABH002+X'008A'.
    2) HP Unload API returns the GE status code erroneously in
       the GNP/GHNP call with two SSAs in APISET 2 or 3 if the 2nd
       SSA contains the segment name at the 3rd or lower level.
       This call type is not supported by HP Unload API.
    

Problem conclusion

  • 1) The module FABH002 has been modified not to refer the
       internal control block.
    2) The module FABHGSA has been modified to treat the GNP/GHNP
       call as unsupported type if the 2nd SSA contains the segment
       name at the 3rd or lower level.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK35959

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-12-08

  • Closed date

    2006-12-14

  • Last modified date

    2007-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK20627

Modules/Macros

  •    FABHGSA  FABH002
    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R110 PSY UK20627

       UP06/12/16 P F612

Fix is available