Error description
If a duplicate DRRN is found after IMS restart, all IMS PA Queues are re-initialized. If the transaction being processed is a Message Switch then R7 will be left pointing to a Transit queue entry that has been freed, thereby causing the S0C4 abend. Keywords: ABENDS0C4 IPIPRTNS IPIMAIN For retro-fit to IMSPA V3.3 fix, see APAR PK36025.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Performance Analyzer V4R1. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 IPIPRTX1 AT X'15A2' * **************************************************************** * RECOMMENDATION: * **************************************************************** S0C4 abend in IPIPRTx1+15A2 If a duplicate DRRN is found after IMS restart, all IMS PA Queues are re-initialised. If the transaction being processed is a Message Switch then R7 will be left pointing to a Transit queue entry that has been freed, thereby causing S0C4 abend.
Problem conclusion
Discard message switch after IMS restart as parent transaction is no longer available.
Temporary fix
Comments
APAR Information
APAR number
PK35637
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-12-04
Closed date
2006-12-18
Last modified date
2007-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK20752
Modules/Macros
IPIPRT71 IPIPRT81 IPIPRT91
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R410 PSY UK20752
UP06/12/20 P F612