IBM Support

PK35574: FRD6002E DBRC RECOV START REQUEST FAILED, RC=04 IS ISSUED WITH NO OTHER EXPLAINATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FRD6002E DBRC RECOV START REQUEST FAILED, RC=04 is issued with
    no other explaination.
    Additional runs produce FRD6022A UNABLE TO RECOVER IXCAUD4
    IXCAUDD4, IMAGE COPY ALREADY TAKEN while attempting to generate
    Incremental Image Copies.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Database Recovery Facility Version 3     *
    *                 Release 1 users who wish to generate         *
    *                 Incremental Image Copies.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The current Incremental Image Copy      *
    *                      capability in DRF allows the user to    *
    *                      generate a batch image copy when the    *
    *                      database is brought offline.  While     *
    *                      the database is still online, any       *
    *                      Incremental Image Copy is generated as  *
    *                      a concurrent image copy.                *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    Users desire an option that will allow DRF to generate a batch
    Incremental Image Copy even while the databases are online.
    The proposed enhancement allows DRF to generate Incremental
    Image Copies up to the latest available batch window or clean
    recovery point that contains a complete change accumulation.
    This process will generate Incremental Image Copies using only
    the prior image copy and the change accumulation.  No logs are
    used.  If a change accumulation is not useable then a copy of
    the prior image copy is generated.
    

Problem conclusion

  • A new OUTPUT(ICRCA) SYSIN option is provided to enhance the
    existing Incremental Image Copy capability.  ICRCA allows the
    user to generate batch Incremental Image Copies even while the
    database is still online.  DRF will search back for the latest
    batch window or recovery point and generate the image copy to
    that time.  Provided that a change accumulation is available
    within that time.  If a batch window does not exist with a
    useable change accumulation then a copy of the prior image copy
    is generated.
    
    FRXMTC and FRXBDMG0 are changed to include new message reason
    codes for MSGFRD6010W and MSGFRD6022A.
    
    FRDEDRF, FRDEDRF0, FRDEPSS0, FRXRVGB, FRXRWSP, and FRXVWSP are
    changed to support a new OUTPUT(ICRCA) option for generating an
    incremental image copy up to the latest available change
    accumulation.
    
    FRXGRPT0 is change to report if OUTPUT(ICRCA) was issued.
    
    FRXICTL0 is changed to use a timestamp supplied by DBRC for the
    incremental image copy that is generated with the OUTPUT(ICRCA)
    option.
    
    FRXPDSS0 is changed to trace pipe communication errors.
    
    FRXRBUF0 is changed to fix an error which identified a change
    accumulation spanned record as an OLR record.
    
    FRXRWCE and FRXRLRA0 are changed to discard any log records
    that may exceed the batch recovery point that is used for the
    incremental image copy.
    
    FRXVADD0 is changed to issue MSGFRD6010W if one or more
    databases used in the OUTPUT(ICRCA) process do not belong to a
    change accumulation group.
    
    FRXVSTA0 is changed to issue MSGFRD6022A if a batch recovery
    point is not found for the OUTPUT(ICRCA) process.  It also
    issues MSGFRD6022A if the change accumulation used is
    incomplete.
    
    ----
    The following DOC changes are made:
    IMS Database Recovery Facility for z/OS
    User's Guide and Reference Version 3 Release 1 (SC18-9407-00)
    
    --
    Chapter 3. Defining and tailoring the IMS Database Recovery
               Facility environment
    
    Modified the existing ICR paragraph description to say:
    
    ICR
        Specifies Incremental Image Copy where a new image copy
        is created from image copy, log, and/or change
        accumulation input data sets for every DBDS in the
        recovery list using the recovery process.  Actual database
        recovery is not performed and the databases are not
        accessed.
    
        In the event you specify OUTPUT(ICR) while the databases
        are offline, the image copy will be registered to the RECON
        as BATCH.
    
        In the event you specify OUTPUT(ICR) while the databases
        are online, the image copy will be registered to the RECON
        as CONCUR.
    
        You cannot specify ICR with any other output option.
    
    --
    Added the following paragraph to describe ICRCA:
    
    ICRCA
        Similar to ICR, but specifies that only a BATCH Incremental
        Image Copy is to be generated using only a prior image copy
        and a change accumulation as input.  Log input is ignored.
    
        DRF will locate and use a timestamp where a clean recovery
        point or batch window exists.  A clean recovery point or
        batch window in this case is defined as a period of time
        where the database was previously brought offline or where
        an OLDS switch occured with logs archived.
    
        DRF will use this timestamp provided that a complete change
        accumulation exists within this time frame.  All databases
        included in the recovery list must belong to the same
        CAGRP.  The resulting Incremental Image Copy will contain
        all updates up to this change accumulation and registered
        as a batch image copy to this time.
    
        If a complete change accumulation is not found within a
        useable bath window then a copy of the prior image copy is
        generated.
    
    ----
    Chapter 7. Messages and Codes of IMS Database Recovery Facility
    
    Added the following new reason codes:
    
    FRD6010W UNABLE TO ADD TO rcvlist, entrytype, entryname: reason
    ...
    NOT IN CAGRP FOR ICRCA
      One or more entries in the recovery list do not belong to a
      CAGRP.  The OUTPUT(ICRCA) option requires that all entries
      belong to a CAGRP.
    ...
    
    FRD6022A UNABLE TO RECOVER: dbname, reason
    ...
    INCOMPLETE CA NOT ALLOWED
      An incomplete change accumulation was detected while
      attempting to generate a batch Incremental Image Copy using
      the ICRCA option.  A complete change accumulation is
      required.
    ...
    NO BATCH ICR POINT FOUND
      DRF attempted to generate a batch Incremental Image Copy and
      was unable to.  A useable batch window does not exist.
    ...
    
    System programmer response:
    
    INCOMPLETE CA NOT ALLOWED
      In order to be able to run with the ICRCA option successfully
      modify your process to ensure that complete change
      accumulations are generated.  Ensure that they are generated
      to a time where no transactions occur against the database.
    ...
    NO BATCH ICR POINT FOUND
      A batch image copy cannot be generated.  Ensure that a
      batch window exists.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK35574

  • Reported component name

    IMS DB RECOVERY

  • Reported component ID

    5655I4400

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-12-01

  • Closed date

    2007-03-01

  • Last modified date

    2007-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK22644

Modules/Macros

  • FRXBDMG0 FRXEDRF  FRXEDRF0 FRXEPSS0 FRXGRPT0
    FRXICTL0 FRXMTC   FRXPDSS0 FRXRBUF0 FRXRLRA0 FRXRVGB  FRXRWCE
    FRXRWSP  FRXVADD0 FRXVSTA0 FRXVWSP
    

Publications Referenced
SC18940700    

Fix information

  • Fixed component name

    IMS DB RECOVERY

  • Fixed component ID

    5655I4400

Applicable component levels

  • R310 PSY UK22644

       UP07/03/06 P F703

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88Z","label":"IMS Database Recovery Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 April 2007