IBM Support

PK35055: OPC PROVIDES INCORRECT OUTPUT REPORTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • OPC shows incorrect output reports:
    1. FPX0073I message is always written with CC=1.
      2. OPC reports don't have a report header.
      3. OPC writes a garbage into SNAPPIT DD.
      4. There are a lot of FPX0115W messages.
    Keywords: MSGFPX0073I MSGFPX0115W
    

Local fix

  • Apply Fix.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Online Pointer Checker users of High     *
    *                 Performance Fast Path Utilities FP Online    *
    *                 Tools Version 2 Release 2 (FMID: H31A220).   *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Message FPX0037I printer control     *
    *                         code error.                          *
    *                      2. No OPC report header.                *
    *                      3. Garbage in the SNAP DUMP.            *
    *                      4. No checking for UOW# of IOVF MAP.    *
    *                      5. Too many message FPX0115Ws.          *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR solves the following 5 problems.
    
    1. Message FPX0037I printer control code error.
    2. No OPC report header.
    3. Garbage in the SNAP DUMP.
    4. No checking for UOW# of IOVF MAP.
    5. Too many message FPX0115Ws.
    

Problem conclusion

  • This APAR has been offered to modify OPC to:
    
    1. Issue message FPX0037I with correct printer control code.
    2. Output OPC report header.
    3. Clear the output field of the SNAP DUMP correctly.
    4. Check consistence of UOW# between IOVF SPACE MAP element and
       IOVF DATA CI, and when OPC detects the differences, OPC
       issues messages as following.
    
       FPX0061E  -> Serious Error:
       FPX0061E IOVF CI ownership error.
       FPX0061E RBA of IOVF Space Map CI: xxxxxxxx
       FPX0061E RBA of target IOVF CI: xxxxxxxx
       FPX0061E Space Map Element Offset: xxxxxxxx
       FPX0061E Space Map Element: xxxxxxxx
       FPX0061E CI Prefix : xxxxxxxxxxxxxxxx
    
    5. Issue message FPX0115W only once per run.
    220Y
    FPXAERR1
    FPXAPRC0
    FPXAPRC7
    FPXAPRC8
    FPXAPRC9
    FPXARPT0
    FPXARPT7
    FPXARPT8
    FPXARPT9
    FPXASDP0
    FPXASNP1
    FPXAVSM0
    FPXCONS0
    FPXENTRY
    FPXEYES
    FPXMAC20
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK35055

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-11-22

  • Closed date

    2006-12-15

  • Last modified date

    2007-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK20673 PK36903

Modules/Macros

  •    FPXAERR1 FPXAPRC0 FPXAPRC7 FPXAPRC8 FPXAPRC9
    FPXARPT0 FPXARPT7 FPXARPT8 FPXARPT9 FPXASDP0 FPXASNP1 FPXAVSM0
    FPXCONS0 FPXENTRY FPXEYES  FPXMAC20
    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R220 PSY UK20673

       UP06/12/16 P F612

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 January 2007