IBM Support

PK34729: WHEN BP SET FOR VERY SMALL SPACE OBJECT COMPARE DOES NOT PUT UNLOAD DATA TO TAPE WSL RUNS S837 U4094

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • User sets up their BP to be very small:
    Space parameters:
         Unit name         ===> SYSDA
         Space unit  . . . ===> TRK
         Max Primary . . . ===> 1
         Max DASD  . . . . ===> 1
         Tape Unit . . . . ===> TAPE
    Then uses Object Compare on a table with millions of rows. The
    unload statement for the data should have gone to TAPE but did
    not. Statement still shows:
    -STA DB(DB89308X) SPACE(TS89308X) ACCESS(RO);
    TSODELETE 'XXXXX.B@89308.B@89308.CNT.T0001';
    TSODELETE 'XXXXX.B@89308.B@89308.ULD.T0001';
    TEMPLATE UTLPUNCH DSN 'XXXXX.B@89308.B@89308.CNT.T0001'
             UNIT SYSDA;
    TEMPLATE UTLREC DSN 'XXXXX.B@89308.B@89308.ULD.T0001'
             UNIT SYSDA;
    UNLOAD DATA FROM TABLE
    "XXXXX"."T89308"
    If WSL is run it fails with:
    IEC028I 837-08,IFG055
    u4094 s837 rc08 rc=4094 4094
    

Local fix

  • Please apply PTF when available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Object Comparison Tool, who use *
    *                 sizable Table and only allocation small DASD *
    *                 space, may be affected.                      *
    *                 .* Note: ie. Requesting unload to tape in    *
    *                 APPLY processing did not get accepted.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: When  BP  were set  up to be very small *
    *                      Space parameters and the Object Compare *
    *                      was  used  on  a table with millions of *
    *                      rows, the unload statement for the data *
    *                      should  have gone to  TAPE but did not. *
    *                      If  WSL  was run it failed with IEC028I *
    *                      837-08,IFG055 U4094 S837 RC08.          *
    *                      .*                                      *
    *                      Max DASD  was set to be small to enable *
    *                      use  of  tape for APPLY job output data *
    *                      sets.  Panel  ADB2UPA  also used a very *
    *                      small primary DASD  allocation. However *
    *                      Object  Compare  outputs  went  to DASD *
    *                      instead of tape.  Space  problems would *
    *                      then follow.                            *
    *                      .* Note:                                *
    *                      Exec GOCGAJOB has been modified to use  *
    *                      tape for the output datasets  for  the  *
    *                      circumstance described.                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    See Problem Description.
    

Problem conclusion

  • Apply the fix.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK34729

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-11-15

  • Closed date

    2006-12-26

  • Last modified date

    2007-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    GOCGAJOB
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • R710 PSY UK20898

       UP06/12/30 P F612

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021