A fix is available
APAR status
Closed as program error.
Error description
QMF can abend with an ABENDS0C4 ABEND0C4 in DSFMCTL when multiple forms are used in a QMF PROC if use of a form that contains BREAKs is followed by use of a form that contains no BREAKs.
Local fix
no Work Around
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO and CICS users, V7.1, * * V7.2, V8.1, and V9.1. * **************************************************************** * PROBLEM DESCRIPTION: An ABENDS0C4 ABEND0C4 can occur in * * DSQFMCTL if a QMF PROC that contains * * more than one FORM is executed. * **************************************************************** * RECOMMENDATION: * **************************************************************** Some variables that describe FORM characteristics were not being reinitialized between uses of different FORMs that are used by a QMF PROCEDURE. A FORM that contained EDIT CODES of BREAK and SUM was followed by a FORM that contained no EDIT CODES, yet the second FORM was processed with a variable set to indicate it contained a BREAK. That flag allowed code to be processed that led to a fetch protection abend.
Problem conclusion
Code was amended in DSQFPREF to reset form flags when a new report is being prepared, and a check of form flags that are used only in conjunction with EDIT CODEs was added to DSQFMCTL.
Temporary fix
Comments
**** PE07/02/13 FIX IN ERROR. SEE APAR PK39338 FOR DESCRIPTION
APAR Information
APAR number
PK34089
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-11-03
Closed date
2006-11-14
Last modified date
2007-02-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK19727 UK19728 UK19729 UK19730
Modules/Macros
DSQFMCTL DSQFPREF
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
R710 PSY UK19727
UP06/11/18 P F611
R720 PSY UK19728
UP06/11/18 P F611
R810 PSY UK19729
UP06/11/18 P F611
R910 PSY UK19730
UP06/11/18 P F611
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: