A fix is available
APAR status
Closed as new function.
Error description
Provide support for IMS V10 ( 10.0 )
Local fix
Apply fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Unload * * for OS/390 Release 1 (FMID=H1IN110) * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables HP Unload to run * * under IMS Version 10. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR enables HP Unload to run under IMS Version 10 and support the following new functions introduced by IMS Version 10: 1. Parallel RECON access If IMS RECON is defined as ACCESS=PARALLEL, IMS DBRC SCI Registration requires IMSplex name and DBRC group ID. User can specify them in the DBRC SCI Registration exit (DSPSCIX0) or in the PARM parameter of the EXEC statement for PGM=FABHX034. Users of FABHULU, FABHDLI, and FABHDBB catalog procedures have to add the IMSPLEX= and PARM1= parameters. See the "1.2.2.3 Parameters required by the IMS DBRC SCI registration" in Documentation Change. 2. z/OS 1.7 DFSMSdfp Large Sequential Data Sets >64k Tracks The unload utilities, FABHURG1, FABHFSU, and IPR Unload utility, support the large format data set for unload data sets if IMS Version 10 is used in z/OS V1R7 or later.
Problem conclusion
Temporary fix
Comments
======================== = Documentation Change = ======================== IBM IMS High Performance Unload for OS/390 User's Guide (SC27-0936-04) should be changed as follows: ================================================================ 1.0 Using High Performance Unload 1.2 Job control language 1.2.2 Supported IMS region types and cataloged procedures |1.2.2.3 Parameters required by the IMS DBRC SCI registration (This subtopic is added newly.) | When the IMS DBRC SCI registration requires the IMSplex name | and the DBRC group identification, you must add the parameters | such as IMSPLEX= or PARM1= to the FABHULU, FABHDLI, and | FABHDBB catalog procedures by yourself as shown in Figure xx. | | // PROC IMSDSN=IMSVS,DBTLMD='HPS.SHPSLMD0',SOUT='*', | // MBR=TEMPNAME,CTRL=DFSRRC00,DBD=,BUF=7, | // SPIE=0,TEST=0,EXCPVR=0,RST=0,PRLD=,SRCH=0, | // CKPTID=,MON=N,LOGA=0,FMTO=T,IMSID=,SWAP=,DBRC=, | // IRLM=,IRLMNM=,IMSPLEX=,PARM1= | //G EXEC PGM=FABHX034,PARM=('&CTRL/ULU',&MBR,&DBD,&BUF, | // &SPIE&TEST&EXCPVR&RST,&PRLD,&SRCH,&CKPTID,&MON, | // &LOGA,&FMTO,&IMSID,&SWAP,&DBRC,&IRLM,&IRLMNM, | // ,,,,,,,,&IMSPLEX,,'&PARM1') | Figure xx. Adding IMSPLEX and PARM1 parameters | to the FABHULU procedure | |In the JCL that uses the FABHULU procedure, you can specify |the parameter values as shown in Figure yy. | | //UNLOAD EXEC FABHULU, | // IMSDSN='IMSVS.SDFSRESL', | // DBTLMD='IMS.SHPSLMD0', | // MBR=FABHFSU, | // DBD=PHDV0100, | // DBRC=Y, | // IRLM=Y, | // IMSPLEX=PLEX1, | // PARM1='DBRCGRP=001' | Figure yy. Example of the parameter specification | for the FABHULU procedure | ================================================================ 1.4 Using FABHURG1 to unload IMS databases 1.4.6 JCL requirements for FABHURG1 : Notes. |1. The LRECL values for SYSUT2 and SYSUT3 data sets are determined as follows: : |2. The large format data set can be specified for SUSUT2 and | SYSUT3 when z/OS Version 1 Release 7 or later | and IMS Version 10 or later are used. ================================================================ 1.5 Using FABHFSU to unload IMS databases 1.5.6 JCL requirements for FABHFSU : ddname1 DD This is the primary output data set containing the unloaded database. One DD statement is required for each PSB control statement (in the CARDIN data set) that specifies an output format other than NO. (ddname1 must be the name specified in the ddname1 field of the PSB control statement. See "PSB control statement" in topic 1.5.7.1.4.) You can have up to three of those data sets. | The large format data set can be specified for those data | sets if z/OS Version 1 Release 7 or later and IMS Version 10 | or later are used. : ================================================================ 4.4 Messages 4.4.2 Message variables 4.4.2.1 FABH messages (The new messages FABH0059E and FABH0316E are added.) ---------------------------------------------------------------- | FABH0059E TRACK NUMBER EXCEEDS 65535 | Explanation: The database data set is larger than 65535 tracks | on a volume. To read such a large format data set, | the level of z/OS must be version 1 release 7 or later. | System Action: HSSR Engine ends abnormally. | Programmer Response: Check the level of z/OS. ---------------------------------------------------------------- | FABH0316E ERROR RETURN FROM IGWASYS (RC=xx, RSN=yy) | Explanation: HSSR Engine called IGWASYS, but an error return | code was returned from IGWASYS. Here, xx is the return code | and yy is the reason code. | System Action: HSSR Engine ends abnormally. | Programmer Response: See DFSMSdfp Advanced Services | and check the meaning of the return code and reason code. ---------------------------------------------------------------- ================= End of Documentation Change ==================
APAR Information
APAR number
PK33118
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-10-18
Closed date
2006-12-26
Last modified date
2007-01-04
APAR is sysrouted FROM one or more of the following:
PK33111
APAR is sysrouted TO one or more of the following:
UK20901 002PC0 002PC0
Modules/Macros
FABHA30 FABHB15X FABHB20 FABHB30 FABHDATE FABHFCKR FABHFPHA FABHFSU FABHFSUA FABHGDLA FABHHSSR FABHHSSX FABHHTBL FABHINI0 FABHKEYX FABHLINK FABHPLIX FABHPSLA FABHRPTH FABHRTI0 FABHTCB FABHTCBU FABHTESA FABHTEST FABHURGA FABHURG1 FABHX034 FABH000 FABH001 FABH002 FABH003A FABH010A FABH011 FABH015 FABH015A FABH020A FABH021 FABH022 FABH030A FABH031 FABH040 FABH041 FABH042A FABH050 FABH060 FABH070 FABH080 FABH081 FABH082 FABH083 FABH090 FABH091 FABH092 FABH093 FABH100 FABH105 FABH110 FABH111 FABH120A FABH130 FABH140 FABH150 FABH160 FABH190 FABH200A FABH201 FABH250A FABH500 FABH510 FABH511 FABH512 FABH513 FABH515A FABH516A FABH520 FABH530 FABH535 FABH540A FABH550 FABH560 FABH620 FABH630A FABH650 FABH660 FABH661 FABH662 FABH663 FABH665 FABH680 FABH681 FABIHTBL FABIUNLA FABIUNLS HPSSHDRH HPSSMSGT HPSSSCAA HPSSSCAN HPSSSEHA HPSUGVT0 HPSUHPTI HPSUHTBL HPSUMAIN HPSUMSGS HPSURIO0 HPSURPTH HPSURR01 HPSURR13 HPSUURGA HPSUURG1 HPSUUSHF H1IN110J
| SC27093604 |
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R110 PSY UK20901
UP06/12/28 P F612
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date:
20 October 2020