Error description

  • S047 Abend occurrs when CRC is executed without FASTIC=(,COPY)
    even if the library specified in STEPLIB is APF authorized.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR includes fixes for following  *
    *                      HPIC V4R1 problems:                     *
    *                                                              *
    *                      1 HPIC Create Image Copy function       *
    *                        terminates with ABEND S047            *
    *                        ( ABEND047 ), when all of the         *
    *                        following conditions are satisfied:   *
    *                        - The input IC data set is taken by   *
    *                          the DFSMSdss COPY.                  *
    *                        - The STEPLIB DD that is APF          *
    *                          authorized.                         *
    *                        - The FASTIC= keyword is not          *
    *                          specified in the ICEIN control      *
    *                          statement.                          *
    *                                                              *
    *                      2 HPIC Recovery function terminates     *
    *                        with ABEND S047 ( ABEND047 ),         *
    *                        when all of the following conditions  *
    *                        are satisfied:                        *
    *                        - The input IC data set is taken by   *
    *                          the DFSMSdss COPY.                  *
    *                        - The STEPLIB DD that is APF          *
    *                          authorized.                         *
    *                        - The HPIO=N and TOIAUTO=N keywords   *
    *                          are specified in the ICEIN control  *
    *                          statement.                          *
    *                                                              *
    *                      3 HPIC Image Copy function ends         *
    *                        normally although it should           *
    *                        terminates with message FABJ4199E     *
    *                        ( MSGFABJ4199E ) and ABEND U0199      *
    *                        ( ABENDU0199 ), when all of the       *
    *                        following conditions are satisfied:   *
    *                        - The STEPLIB DD is not APF           *
    *                          authorized.                         *
    *                        - GROUP statement is specified in the *
    *                          ICEIN control statement.            *
    *                        - HPIO=Y or TOIAUTO=Y is specified in *
    *                          the ICEIN control statement.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR includes fixes for following HPIC V4R1 problems:
    
    1 HPIC Create Image Copy function terminates with ABEND S047
      ( ABEND047 ), when all of the following conditions are
      satisfied:
      - The input IC data set is taken by the DFSMSdss COPY.
      - The STEPLIB DD that is APF authorized.
      - The FASTIC= keyword is not specified in the ICEIN control
        statement.
    
    2 HPIC Recovery function terminates with ABEND S047
      ( ABEND047 ), when all of the following conditions are
      satisfied:
      - The input IC data set is taken by the DFSMSdss COPY.
      - The STEPLIB DD that is APF authorized.
      - The HPIO=N and TOIAUTO=N keywords are specified in the ICEIN
        control statement.
    
    In the above cases, HPIC does not get the parameter that is
    necessary for MODE change. So HPIC tries to change into the
    supervisor mode without an authorization, then terminates with
    abend.
    
    3 HPIC Image Copy function ends normally although it should
      terminates with message FABJ4199E ( MSGFABJ4199E ) and
      ABEND U0199 ( ABENDU0199 ), when all of the following
      conditions are satisfied:
      - The STEPLIB DD is not APF authorized.
      - GROUP statement is specified in the ICEIN control statement.
      - HPIO=Y or TOIAUTO=Y is specified in the ICEIN control
        statement.
    
    In the above case 3, HPIC refers the invalid control block.
    So HPIC mishandles the APF check process, then HPIC ends
    normally although HPIC should terminated with abend.
    

Problem conclusion

  • FABJMAIN has been modified to check the right control block when
    GROUP statement is specified and to check APF status correctly.
    
    FABJRPC0 has been modified to get a PC number, when the STEPLIB
    DD is APF authorized even if the caller's request is
    "Authorization OFF".
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK31006

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-09-06

  • Closed date

    2006-09-12

  • Last modified date

    2006-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK17901

Modules/Macros

  • FABJMAIN FABJRPC0
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK17901

       UP06/09/13 P F609

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020