Error description
S047 Abend occurrs when CRC is executed without FASTIC=(,COPY) even if the library specified in STEPLIB is APF authorized.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR includes fixes for following * * HPIC V4R1 problems: * * * * 1 HPIC Create Image Copy function * * terminates with ABEND S047 * * ( ABEND047 ), when all of the * * following conditions are satisfied: * * - The input IC data set is taken by * * the DFSMSdss COPY. * * - The STEPLIB DD that is APF * * authorized. * * - The FASTIC= keyword is not * * specified in the ICEIN control * * statement. * * * * 2 HPIC Recovery function terminates * * with ABEND S047 ( ABEND047 ), * * when all of the following conditions * * are satisfied: * * - The input IC data set is taken by * * the DFSMSdss COPY. * * - The STEPLIB DD that is APF * * authorized. * * - The HPIO=N and TOIAUTO=N keywords * * are specified in the ICEIN control * * statement. * * * * 3 HPIC Image Copy function ends * * normally although it should * * terminates with message FABJ4199E * * ( MSGFABJ4199E ) and ABEND U0199 * * ( ABENDU0199 ), when all of the * * following conditions are satisfied: * * - The STEPLIB DD is not APF * * authorized. * * - GROUP statement is specified in the * * ICEIN control statement. * * - HPIO=Y or TOIAUTO=Y is specified in * * the ICEIN control statement. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR includes fixes for following HPIC V4R1 problems: 1 HPIC Create Image Copy function terminates with ABEND S047 ( ABEND047 ), when all of the following conditions are satisfied: - The input IC data set is taken by the DFSMSdss COPY. - The STEPLIB DD that is APF authorized. - The FASTIC= keyword is not specified in the ICEIN control statement. 2 HPIC Recovery function terminates with ABEND S047 ( ABEND047 ), when all of the following conditions are satisfied: - The input IC data set is taken by the DFSMSdss COPY. - The STEPLIB DD that is APF authorized. - The HPIO=N and TOIAUTO=N keywords are specified in the ICEIN control statement. In the above cases, HPIC does not get the parameter that is necessary for MODE change. So HPIC tries to change into the supervisor mode without an authorization, then terminates with abend. 3 HPIC Image Copy function ends normally although it should terminates with message FABJ4199E ( MSGFABJ4199E ) and ABEND U0199 ( ABENDU0199 ), when all of the following conditions are satisfied: - The STEPLIB DD is not APF authorized. - GROUP statement is specified in the ICEIN control statement. - HPIO=Y or TOIAUTO=Y is specified in the ICEIN control statement. In the above case 3, HPIC refers the invalid control block. So HPIC mishandles the APF check process, then HPIC ends normally although HPIC should terminated with abend.
Problem conclusion
FABJMAIN has been modified to check the right control block when GROUP statement is specified and to check APF status correctly. FABJRPC0 has been modified to get a PC number, when the STEPLIB DD is APF authorized even if the caller's request is "Authorization OFF".
Temporary fix
Comments
APAR Information
APAR number
PK31006
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-09-06
Closed date
2006-09-12
Last modified date
2006-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK17901
Modules/Macros
FABJMAIN FABJRPC0
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK17901
UP06/09/13 P F609
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020