Error description

  • The "Defaults" panel has a field for entering the log reading
    parallelism maximum, and the value should be entered as a two
    digit number. If entered as a one digit number, an ABEND0C7
    (S0C7) can occur while generating JCL. The obvious workaround
    is to enter it as a two digit number (e.g., 02 rather than 2)
    if this APAR is not yet applied.
    
    If the value is left as 2, and the APAR is applied, the
    "Defaults" panel must still be entered once thereafter and the
    values saved. The APAR affects the code at the "Defaults" panel
    level, requiring this entry into the "Defaults" panel prior to
    successfully generating other JCL without a S0C7.
    

Local fix

  • Enter the log reading parallelism maximum as a two digit number
    (e.g., 02 rather than 2) if this APAR is not yet applied.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Log Analysis Tool.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The "Defaults" panel has a field for    *
    *                      entering the log reading parallelism    *
    *                      maximum, and the value should be        *
    *                      entered as a two digit number. If it is *
    *                      entered as a one digit number, a S0C7   *
    *                      can occur while generating JCL. The     *
    *                      obvious workaround is to enter it as a  *
    *                      two digit number (e.g., 02 rather than  *
    *                      2) if this APAR is not yet applied. If  *
    *                      the value is left as 2, and the APAR is *
    *                      applied, the "Defaults" panel must      *
    *                      still be entered once thereafter and    *
    *                      the values saved. The APAR affects the  *
    *                      code at the "Defaults" panel level,     *
    *                      requiring this entry into the           *
    *                      "Defaults" panel prior to successfully  *
    *                      generating other JCL without a S0C7.    *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK30111

  • Reported component name

    DB2 LOG ANALYSI

  • Reported component ID

    5655E6601

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-08-17

  • Closed date

    2006-09-06

  • Last modified date

    2007-04-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ALAUNCRE
    

Fix information

  • Fixed component name

    DB2 LOG ANALYSI

  • Fixed component ID

    5655E6601

Applicable component levels

  • R230 PSY UK17795

       UP06/09/13 P F609

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230"}]

Document Information

Modified date: