IBM Support

PK29544: ISPF ONLINE MONITOR INTERFACE, SPLIT SCREEN SHOULD NOT CAUSE AN ABENDS0C4.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Performing a slip screen from the OMPE Online Monitor and
    trying to get into thread panel option 3 user experiences
    IEA995I SYMPTOM DUMP OUTPUT
    SYSTEM COMPLETION CODE=0C1  REASON CODE=00000001
     TIME=11.03.24  SEQ=52739  CPU=0000  ASID=010F
     PSW AT TIME OF ERROR  078D1000   80000002  ILC 2  INTC 01
       NO ACTIVE MODULE FOUND
       NAME=UNKNOWN
       DATA AT PSW  00000000 - 000A0000  000130E1  00000000
       GR 0: 00000000   1: 001DDB60
          2: 001D6134   3: 001D6420
          4: 001D6404   5: 00BFE348
          6: 001C77B4   7: 99999999
          8: 001C77B5   9: 99999999
          A: 001DD8CF   B: 07700CE8
          C: 801DC8D0   D: 001DDE0C
          E: 801DCACE   F: 00000000
     END OF SYMPTOM DUMP
    Abend 0C1000 hex occurred processing command 'FPEMMAIN'.
    ***
    
    ISPD210
    
     CMD abended
     'FPEMMAIN' terminated abnormally.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM V310            *
    *                 users of component:                          *
    *                 - ISPF Monitoring dialogs                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Performing a split screen from the OMPE *
    *                      Online Monitor and trying to get into   *
    *                      thread panel option 3 user experiences  *
    *                      IEA995I SYMPTOM DUMP OUTPUT.            *
    *                      SYSTEM COMPLETION CODE=0C1.             *
    *                      FPEMMAIN terminated abnormally.         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Performing a split screen from the OMPE Online Monitor and
    trying to get into thread panel option 3 user experiences
    IEA995I SYMPTOM DUMP OUTPUT. SYSTEM COMPLETION CODE=0C1.
    FPEMMAIN terminated abnormally.
    

Problem conclusion

  • Performing a split screen from the OMPE Online Monitor and
    trying to get into thread panel option 3 user experiences
    IEA995I SYMPTOM DUMP OUTPUT. SYSTEM COMPLETION CODE=0C1.
    FPEMMAIN terminated abnormally.
    ----------------------------------------------------------------
    Trying to start the OMPE Online Monitor in a ISPF split screen
    session results in message
    "FPEU0015I Second session not supported".
    ----------------------------------------------------------------
    SYSMOD TITLE: ISPFOLM split screen session
    KEYWORDS:     ISPFOLM SPLITSCREEN
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK29544

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-08-08

  • Closed date

    2006-10-16

  • Last modified date

    2007-07-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK18835 PK48868

Modules/Macros

  •    FPEFMAIN
    

Publications Referenced
GC18963801    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK18835

       UP06/10/17 P F610

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: