Error description
Performing a slip screen from the OMPE Online Monitor and trying to get into thread panel option 3 user experiences IEA995I SYMPTOM DUMP OUTPUT SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 TIME=11.03.24 SEQ=52739 CPU=0000 ASID=010F PSW AT TIME OF ERROR 078D1000 80000002 ILC 2 INTC 01 NO ACTIVE MODULE FOUND NAME=UNKNOWN DATA AT PSW 00000000 - 000A0000 000130E1 00000000 GR 0: 00000000 1: 001DDB60 2: 001D6134 3: 001D6420 4: 001D6404 5: 00BFE348 6: 001C77B4 7: 99999999 8: 001C77B5 9: 99999999 A: 001DD8CF B: 07700CE8 C: 801DC8D0 D: 001DDE0C E: 801DCACE F: 00000000 END OF SYMPTOM DUMP Abend 0C1000 hex occurred processing command 'FPEMMAIN'. *** ISPD210 CMD abended 'FPEMMAIN' terminated abnormally.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM V310 * * users of component: * * - ISPF Monitoring dialogs * **************************************************************** * PROBLEM DESCRIPTION: Performing a split screen from the OMPE * * Online Monitor and trying to get into * * thread panel option 3 user experiences * * IEA995I SYMPTOM DUMP OUTPUT. * * SYSTEM COMPLETION CODE=0C1. * * FPEMMAIN terminated abnormally. * **************************************************************** * RECOMMENDATION: * **************************************************************** Performing a split screen from the OMPE Online Monitor and trying to get into thread panel option 3 user experiences IEA995I SYMPTOM DUMP OUTPUT. SYSTEM COMPLETION CODE=0C1. FPEMMAIN terminated abnormally.
Problem conclusion
Performing a split screen from the OMPE Online Monitor and trying to get into thread panel option 3 user experiences IEA995I SYMPTOM DUMP OUTPUT. SYSTEM COMPLETION CODE=0C1. FPEMMAIN terminated abnormally. ---------------------------------------------------------------- Trying to start the OMPE Online Monitor in a ISPF split screen session results in message "FPEU0015I Second session not supported". ---------------------------------------------------------------- SYSMOD TITLE: ISPFOLM split screen session KEYWORDS: ISPFOLM SPLITSCREEN
Temporary fix
Comments
APAR Information
APAR number
PK29544
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-08-08
Closed date
2006-10-16
Last modified date
2007-07-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK18835 PK48868
Modules/Macros
FPEFMAIN
| GC18963801 |
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R310 PSY UK18835
UP06/10/17 P F610
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 July 2007