Error description

  • This APAR will add to the functionality of ATF processing in two
    ways.
    1) A new option "FLUSH=" has been added to the ATF options
    screen, ATRQ. The FLUSH option specifies the frequency (in
    seconds) at which ATF processing will write its internal buffers
    to the VSAM trace dataset.
    2) The maximum value of the overall tracing interval has been
    increased in screen ATRQ. The value can now be specified for
    a period of up to 9998 minutes. Additionally, an
    unlimited trace interval can be indicated by specifying a TIME
    value of either 1440 or 9999. In order to enable this feature,
    usermod KO2MOD01 must be installed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of OMEGAMON XE for DB2 PE/DB2PM V310   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Allow for unlimited trace interval.     *
    *                      Externalize FLUSH interval.             *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    Enhancement
    

Problem conclusion

Temporary fix

Comments

  • Enhancement:
    The usermod permits changes to the defaults and maximums
    used by ATF processing. One of those maximums is the
    maximum trace interval, which affects the 'TIME=' field
    on screen ZATRQ.
    By default, this maximum is 60 minutes. If you are happy
    with this limit then no further action is required after
    installing the PTF.
    However, in order to allow for unlimited tracing by users,
    USERMOD KO2MOD01 must be applied, and the maximum
    trace time value set to 9999. The updated USERMOD is found
    in the hilev.TKANSAM library. These actions are described
    in detail within the USERMOD itself. Once the USERMOD
    has been applied, users can then specify on screen ZATRQ
    either 1440 or 9999 to indicate an unlimited trace time,
    or any other value, which will be interpreted as an exact
    number of minutes.
    ----------------------
    SYSMOD Title: Enhancements to ATF processing
    Keywords:     ATF FLUSH TIME INTERVAL
    

APAR Information

  • APAR number

    PK28757

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-07-27

  • Closed date

    2006-09-15

  • Last modified date

    2006-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK17747

Modules/Macros

  •    KD2PSA2P KD2UTDCL KO2ACAFS KO2ACAF2 KO2ACAPS
    KO2ACAP2 KO2ASUBS KO2ASUB2 KO2ATRCB KO2ATRPB KO2ATRQH KO2ATVWH
    KO2AUSRB KO2CNTPS KO2CNTP2 KO2ICAFS KO2ICAF2 KO2MOD01 KO2ODCNB
    KO2OTHDB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK17747

       UP06/09/16 P F609

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 October 2006