Error description
This APAR will add to the functionality of ATF processing in two ways. 1) A new option "FLUSH=" has been added to the ATF options screen, ATRQ. The FLUSH option specifies the frequency (in seconds) at which ATF processing will write its internal buffers to the VSAM trace dataset. 2) The maximum value of the overall tracing interval has been increased in screen ATRQ. The value can now be specified for a period of up to 9998 minutes. Additionally, an unlimited trace interval can be indicated by specifying a TIME value of either 1440 or 9999. In order to enable this feature, usermod KO2MOD01 must be installed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of OMEGAMON XE for DB2 PE/DB2PM V310 * **************************************************************** * PROBLEM DESCRIPTION: Allow for unlimited trace interval. * * Externalize FLUSH interval. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** Enhancement
Problem conclusion
Temporary fix
Comments
Enhancement: The usermod permits changes to the defaults and maximums used by ATF processing. One of those maximums is the maximum trace interval, which affects the 'TIME=' field on screen ZATRQ. By default, this maximum is 60 minutes. If you are happy with this limit then no further action is required after installing the PTF. However, in order to allow for unlimited tracing by users, USERMOD KO2MOD01 must be applied, and the maximum trace time value set to 9999. The updated USERMOD is found in the hilev.TKANSAM library. These actions are described in detail within the USERMOD itself. Once the USERMOD has been applied, users can then specify on screen ZATRQ either 1440 or 9999 to indicate an unlimited trace time, or any other value, which will be interpreted as an exact number of minutes. ---------------------- SYSMOD Title: Enhancements to ATF processing Keywords: ATF FLUSH TIME INTERVAL
APAR Information
APAR number
PK28757
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-07-27
Closed date
2006-09-15
Last modified date
2006-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK17747
Modules/Macros
KD2PSA2P KD2UTDCL KO2ACAFS KO2ACAF2 KO2ACAPS KO2ACAP2 KO2ASUBS KO2ASUB2 KO2ATRCB KO2ATRPB KO2ATRQH KO2ATVWH KO2AUSRB KO2CNTPS KO2CNTP2 KO2ICAFS KO2ICAF2 KO2MOD01 KO2ODCNB KO2OTHDB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R310 PSY UK17747
UP06/09/16 P F609
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]