A fix is available
APAR status
Closed as program error.
Error description
With apar PK19203 applied, the customer is still receiving a problem where when issuing an EXEC CICS WRITE OPERATOR TEXT request with a TEXTLENGTH between 114 and 129, the text is not written to the console. The actual length of the text is 52 characters. The WRITE OPERATOR returns a NORMAL response, but the text messages are still not written to the console.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: PTF UK15442 does not fix the problem * * reported by APAR PK19203. * **************************************************************** * RECOMMENDATION: * **************************************************************** PTF UK15442 does not fix the problem reported by APAR PK19203. That is, for some combinations of TEXTLENGTH and the actual length of the text in an EXEC CICS WRITE OPERATOR command the text is not sent to the console even though the command returns a NORMAL response. It is also possible for a line of blanks to be issued when the length of the text makes the calculation of TEXTLENGTH (length of text) greater than 69 in DFHSUWT. PTF UK15442 changed DFHSUWT which should be part of DFHSIP31 and also exist as a standalone module but only DFHSIP31 was built by PTF UK15442. The problem was caused by an error in the PTF build process. Additional keywords: PQ76906 CECI
Problem conclusion
UK15442 The error in the PTF build process has been corrected so that future PTFs containing DFHSUWT will be correct.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PK28356
Reported component name
CICSTS FOR VSE
Reported component ID
564805400
Reported release
B0P
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-07-19
Closed date
2006-08-11
Last modified date
2007-02-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK17162
Modules/Macros
DFHSUWT
Fix information
Fixed component name
CICSTS FOR VSE
Fixed component ID
564805400
Applicable component levels
RB0P PSY UK17162
UP06/08/22 P E410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: