A fix is available
APAR status
Closed as new function.
Error description
THIS APAR PROVIDES NEW FUNCTION
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 3 Release 2 users ( FMID=H1J0320 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR includes fixes for following * * HPIC V4R1 problems: * * * * 1. HPIC Type-B Image Copy function * * terminates with ABEND S0C4 * * ( ABEND0C4 ) when all of the * * following conditions are satisfied: * * - ICTYPE=B is specified in the HPSIN * * control statement * * - The first IC/AIC statement * * that is about unnecessary DBD for * * IMS Parallel Reorganization is * * specified in the ICEIN control * * statement * * * * 2. HPIC V3R2 Image Copy function * * terminates with an unexpected * * error, when running HPIC with z/OS * * diagnostic test tool IGVINITGETMAIN * * (dirty getmain) enabled. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * * This APAR level is required to run under * * IMS Paralell Reorganization for z/OS, * * Version 3 Release 2 (FMID H25N320). * **************************************************************** This APAR includes fixes for following HPIC V4R1 problems: 1. HPIC Type-B Image Copy function terminates with ABEND S0C4 ( ABEND0C4 ) when all of the following conditions are satisfied: - ICTYPE=B is specified in the HPSIN control statement - The first IC/AIC statement that is about unnecessary DBD for IMS Parallel Reorganization is specified in the ICEIN control statement In these conditions, HPIC terminates without creating image copy data sets and misreads the ECB area. 2. HPIC V3R2 Image Copy function terminates with an unexpected error, when running HPIC with z/OS diagnostic test tool IGVINITGETMAIN (dirty getmain) enabled. Some of the unexpected errors are following things: - HPIC V3R2 issues IEA705I 878-18 ( MSGIEA705I RSN18 ) and terminates with ABEND S878 ( ABEND878 ) RSN=18. terminates with ABEND S878 ( ABEND878 ) RSN=18. - HPIC V3R2 issues IEA705I 978-04 ( MSGIEA705I RSN4 ) and terminates with ABEND S978 ( ABEND978 ) RSN=04. Because the GETMAINed storage is dirty (non-zero), HPIC misreads the control block and mishandles the image copy process. So, HPIC tries to freemain the storage that is not obtained and fails freemain.
Problem conclusion
Temporary fix
Comments
FABJICDD has been modified to set wait flag for 1st entry. The following modules have been modified to clear GETMAINed storage (zeroed). FABUCHG FABJACQG FABJCMP3 FABJCMP4 FABJDEMP FABJDPSN FABJDPUT FABJDRQS FABJNTFI FABJPARM FABJPRM2 FABJPRM3 FABJRETC FABJDOPN FABUFIG1 FABJXLIM FABJMAS2 FABJSAS1 FABJRDB9 The following modules have been reassembled. FABJBUF1 FABJDPS7 FABJDPS8 FABJDPS9 FABJGWTO FABJMSGC FABJRETM FABJFIG1
APAR Information
APAR number
PK28110
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-07-13
Closed date
2006-08-14
Last modified date
2006-09-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK17157
Modules/Macros
FABJACQG FABJAPIM FABJATRC FABJBLKD FABJBUF1 FABJCMDB FABJCMP3 FABJCMP4 FABJCRC0 FABJCRC1 FABJCTCV FABJCZCV FABJDALC FABJDALO FABJDALS FABJDBCM FABJDBC1 FABJDBDN FABJDBD7 FABJDBD8 FABJDBD9 FABJDBF0 FABJDBLK FABJDBRC FABJDBR7 FABJDBR8 FABJDBR9 FABJDCTL FABJDEMP FABJDMPN FABJDMP0 FABJDMP7 FABJDMP8 FABJDMP9 FABJDOPN FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9 FABJDPUT FABJDREQ FABJDRQS FABJFIG1 FABJGVT FABJGVT0 FABJGWTO FABJICDD FABJIDXN FABJIDX7 FABJIDX8 FABJIDX9 FABJINT1 FABJINT2 FABJINT3 FABJIPRC FABJMAIN FABJMAS1 FABJMAS2 FABJMDPN FABJMDP7 FABJMDP8 FABJMDP9 FABJMRGE FABJMSGC FABJNTFC FABJNTFI FABJORCN FABJORC7 FABJORC8 FABJORC9 FABJPARM FABJPRM2 FABJPRM3 FABJRCHK FABJRCH7 FABJRCH8 FABJRCH9 FABJRDB7 FABJRDB8 FABJRDB9 FABJRETC FABJRETM FABJRPT0 FABJSAS1 FABJSAS2 FABJTERM FABJTGEN FABJUIC1 FABJXLIM FABUCHG FABUFIG1 FABUITCT HPSGGSTB
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R320 PSY UK17157
UP06/08/15 P F608
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"320","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020