APAR status
Closed as program error.
Error description
Removal of VOLSER, VOLSER2 and SPACE keyword restrictions when invoking the IC option.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS Database Recovery Facility Version 3 * * Release 1 users. * **************************************************************** * PROBLEM DESCRIPTION: When users generate image copy output * * with DRF they are required to provide * * the SPACE and VOLSER keywords in the * * SYSIN. Users expressed a desire to * * have these requirements removed. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** DRF required the user to provide the VOLSER and SPACE keywords in their recovery job SYSIN. This requirement was initially used to prevent potential failures and abends from HPIC. Some users use a tape library management system and identified that the manual control of VOLSER and SPACE in the DRF environment is uneccessary.
Problem conclusion
DRF is changed to remove the requirement that the user needs to provide the VOLSER, and SPACE parameters for image copy generation. ---- The following doc changes are required: IMS Database Recovery Facility for z/OS, V3R1, User's Guide (SC18-9407-00) Chapter 5. Starting the IMS Database Recovery Facility Change the following paragraph: SPACE= allowed as is and is passed from IMS Database Recovery Facility master to all IMS Database Recovery Facility subordinate address spaces that all HPIC; therefore, it should accommodate all output IC data sets. This is a required parameter. Change it to: SPACE= allowed as is and is passed from IMS Database Recovery Facility master to all IMS Database Recovery Facility subordinate address spaces for HPIC; therefore, it should accommodate all output IC data sets. SPACE is ignored if writing out to tape. This parameter is optional. Change the following paragraph: UNIT, UNIT2, VOLCNT, VOLSER, VOLSER2= allowed as-is and are passed to the IMS Database Recovery Facility subordinate address spaces for communication to HPIC by way of that API. Because dynamic allocation is used, IMS Database Recovery Facility must ensure that these are set and that they are set up correctly. If you are creating a primary output image copy data set, UNIT is the required parameter. You can also specify a value for VOLSER. If a VOLSER value is not provided, then a scratch volume is used. If you are creating a secondary output image copy data set, UNIT2 is the required parameter. Again you can specify a value for VOLSER2. If a VOLSER2 value is not provided, then a scrach volume is used for the secondary output image copy data set. Change it to: UNIT, UNIT2, VOLCNT, VOLSER, VOLSER2= allowed as-is and are passed to the IMS Database Recovery Facility subordinate address spaces for communication to HPIC by way of that API. Because dynamic allocation is used, you should ensure that these are set up correctly. UNIT and UNIT2 are required parameters to identify the unit types you'll be using for your primary and/or secondary output image copy data sets. VOLSER and VOLSER2 can be specified to provide a list of volumes for your primary and secondary output image copy data sets. If these parameters are not provided then a local scratch volume is used. ---- Chapter 7. Messages and Codes of IMS Database Recovery Facility Add a new message code for the following messages: FRD4284E DATA SET RESTORE I/O ERROR, dbd ddn: reason ... INVALID VOLUME FOR OUTPUT IC One or more of the tape volumes you provided with either the VOLSER or VOLSER2 parameters cannot be used. This can be because your input image copy already resides on this tape volume. FRD6124A INVALID DATA ENCOUNTERED. KEYWORD: keyword RSN=rsn ... VOLSER IS REJECTED FROM IC KEYWORD If you are generating STACK image copies and specified VOLSER or VOLSER2 on the individual ADD statements with the IC() keyword, then you need to move them to the UTILGBL statement. Specifying VOLSER and VOLSER2 on the UTILGBL statement ensures that the image copy stack will be generated with a consistent tape volume list. -- Change the following message code for the following message: FRD6124A INVALID DATA ENCOUNTERED. KEYWORD: keyword RSN=rsn ... VALUE OF SPACE OR UNIT IS MISSING WHILE IC KEYWORD SPECIFIED SPACE and UNIT are required parameters if you have specified the IC keyword. Change it to: UNIT IS NEEDED IF IC KEYWORD IS SPECIFIED If you specified the IC keyword to generate an output image copy with DRF, UNIT is a required parameter.
Temporary fix
Comments
APAR Information
APAR number
PK27719
Reported component name
IMS DB RECOVERY
Reported component ID
5655I4400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-07-06
Closed date
2006-08-03
Last modified date
2006-09-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK16995
Modules/Macros
FRXBDMG0 FRXEDRF0 FRXEPSS0 FRXICAI0 FRXICTL0 FRXIDYN0 FRXIRTH0 FRXMTC FRXPDSS0 FRXPSDR0 FRXRVIC FRXRVRT FRXRWAE FRXRWCE FRXRWSP FRXVADD0 FRXVASD0 FRXVWSP
SC18940700 |
Fix information
Fixed component name
IMS DB RECOVERY
Fixed component ID
5655I4400
Applicable component levels
R310 PSY UK16995
UP06/08/09 P F608
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88Z","label":"IMS Database Recovery Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]