A fix is available
APAR status
Closed as program error.
Error description
IMSPLEX= keyword is removed from ICEIN and document the altenative method in a document change.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: IMSPLEX= parameter keyword is * * eliminated, because IMSPLEX= parameter * * keyword should be specified on the EXEC * * parameter. * **************************************************************** * RECOMMENDATION: * **************************************************************** IMSPLEX= parameter keyword is eliminated, because IMSPLEX= keyword should be specified on the EXEC parameter. e.g) PGM=FABJMAIN,PARM='IMSPLEX=plex_name',REGION=0M
Problem conclusion
FABJPARM has been modified to ignore IMSPLEX= parameter keyword in ICEIN. FABJMSGC has been modified to add the FABJ0201I message. ======================== = DOCUMENTATION CHANGE = ======================== IMS High Performance Image Copy for z/OS Version 4 Release 1 User's Guide SC18-9409 ( SC189409 ) should be changed as follows: Modify following description: Chapter 2 Operating Instructions 2.2.1 FABJMAIN JCL The actual JCL requirements are as follows: EXEC This statement must be in the following format: // EXEC PGM=FABJMAIN,PARM='IMSPLEX=plex_name',REGION=0M Note: If you need to specify IMSPLEX name for HPIC process, you should provide IMSPLEX=plex_name in EXEC parameter. Delete the following keyword. Chapter 2 Operating Instructions 2.3 Input - IMSPLEX Delete the following keyword. Chapter 2 Operating Instructions 2.3 Input 2.3.4 HPIC Control Statements 2.3.4.1 GLOBSAL Statements - IMSPLEX Delete the following keyword. 2.3.5 ICEIN Keywords Table 10. ICEIN Keywords IMSPLEX=ccc Delete the following section. 2.3.5 ICEIN Keywords 2.3.5.39 IMSPLEX= Chapter A Appendix A. Return Codes, Abend Codes, and Messages Add following section. A.3.x FABJ0201I | FABJ0201E IMSPLEX= KEYWORD IS IGNORED | Explanation: IMSPLEX= parameter keyword specified in ICEIN | is ignored. It is not supported as ICEIN keyword. | System action: HPIC continues processing. | Programmer response: If necessary, change the specification | of IMSPLEX= parameter keyword to the EXEC parameter, and | rerun the job.
Temporary fix
Comments
APAR Information
APAR number
PK27225
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-06-27
Closed date
2006-07-13
Last modified date
2006-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK16253
Modules/Macros
FABJMSGC FABJPARM
| SC18940900 |
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK16253