Error description

  • This APAR is an enhancement that provides the following new
    options for Integrity Checker:
    
    1. New option to specify whether Integrity Checker automatically
    creates an RDE during the first access to a database.
    
    2. New option to specify whether Integrity Checker abnormally
    ends when its initialization fails.
    

Local fix

  • 
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for Z/OS,    *
    *                 Version 1 Release 1 (FMID=H27P110) users     *
    *                 who use Integrity Checker                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: This enhancement to Integrity Checker   *
    *                      provides two new options, RDEBUILD= and *
    *                      INITERR=, to a global option module.    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR enhances LIU Integrity Checker as follows:
    
    1. Add a new option RDEBUILD= to a global option module. You can
       choose whether to let Integrity Checker automatically create
       an RDE.
    
    2. Add a new option INITERR= to a global option module. You can
       choose whether to let Integrity Checker end abnormally when
       its initialization fails.
    
    You can create a global option module with these new options by
    specifying them in the SYSIN input stream of the FABLPGEN job.
    

Problem conclusion

  • 
    

Temporary fix

  • 
    

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS Library Integrity Utilities for z/OS Version 1 Release 1
    User's Guide (Document Number: SC18-7025-02) should be changed
    as follows.
    ================================================================
     2.1 Overview
     2.1.3 What is a global option module
    
     A global option module provides the following information to
     Integrity Checker:
    
    << Add the following information to the global option module. >>
    
    | o Option values to control the processing of Integrity
    |   Checker
    
    
     2.4 Using global option modules
     2.4.2 Running the FABLPGEN job
    << Add the following new options. >>
    
    |RDEBUILD=
    | Specifies the value for the option to determine whether to let
    | Integrity Checker automatically build an RDE. The system
    | default value for this parameter is Y.
    |
    | Y
    |  If there is no current RDE for a DEDB database, a non-HALDB
    |  database, or a HALDB partition, Integrity Checker
    |  automatically builds an RDE during the first access to the
    |  database or the partition.
    | N
    |  Even if there is no current RDE for a DEDB database, a
    |  non-HALDB database, or a HALDB partition, Integrity Checker
    |  does not build an RDE during the first access to the database
    |  or the partition.
    |
    |INITERR=
    | Specifies the value for the option to determine whether
    | Integrity Checker abnormally ends, or issues a warning message
    | and stops its processing, when the initialization of Integrity
    | Checker fails. The system default value for this parameter is
    | A.
    |
    | A
    |  If the initialization of Integrity Checker fails, it ends
    |  abnormally together with the IMS online subsystem or the IMS
    |  batch job.
    | W
    |  If the initialization of Integrity Checker fails, it issues a
    |  warning message and stops its processing. The IMS online
    |  subsystem or the IMS batch job continues processing without
    |  the Integrity Checker function. However, Integrity Checker
    |  ends abnormally if errors happen before the effective value
    |  for this option is decided. The errors are the load failures
    |  of the following modules:
    |   o FABLRDRx (x: 8 or 9)
    |   o FABLWM0
    |   o FABLAI0
    |   o Global option module
    
    
     B.4.1 FABL messages
    << Add the following new message. >>
    
    |FABL0110W LIU INTEGRITY CHECKER STOPPED PROCESSING
    |
    |Explanation: The LIU integrity checker could not successfully
    |complete its initialization. The LIU integrity checker
    |processing was stopped, because INITERR=W was specified in the
    |global option module.
    |
    |System action: The IMS online subsystem or the IMS batch region
    |continues processing without the LIU integrity checker function
    |
    |Problem determination: Read the preceding messages that explain
    |the error conditions.
    |
    |Programmer response: If necessary, correct the error conditions
    |and restart the IMS online subsystem or rerun the batch job.
    

APAR Information

  • APAR number

    PK26207

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    110

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2006-06-07

  • Closed date

    2006-06-23

  • Last modified date

    2006-07-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK15677

Modules/Macros

  •    FABLAGOP FABLAI0  FABLAI1  FABLIVS0 FABLPGIN
    FABLVMN0 FABLVMN8 FABLVMN9 FABLWMT
    

Publications Referenced
SC18702502

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R110 PSY UK15677

       UP06/06/26 P F606

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]

Document Information

Modified date:
30 March 2021