IBM Support

PK25976: FPEV0263E DB2Z AUTOMATIC EXCP NOT STARTED - NO VALID THRESHOLD RECORDS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When starting the OMEGAMON XE/PE server with an empty threshold
    dataset or if the dataset has been populated with the contents
    of RKO2DATA(DGOETV41) (as per Ch6 of the Monitoring from ISPF
    Monitor manual.) we get message
    FPEV0263E DB2Z AUTOMATIC EXCP NOT STARTED - NO VALID THRESHOLD
    RECORDS
    It has been found member DGOETV41 has invalid records.
    

Local fix

  • After ensuring the threshold dataset is empty, create an
    exception record using the ISPF PE panel option 4. Restart
    OMEGDB2 and the the automatic exception processing should start
    ok. IE message FPEV0261I  DB2Z AUTOMATIC EXCP STARTED will be
    received
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM V310            *
    *                 users of component:                          *
    *                 -   OMEGAMON Server                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: When using the example threshold        *
    *                      dataset RKO2DATA(DGOETV41)              *
    *                      the server considers all                *
    *                      thresholds within that dataset          *
    *                      to be invalid. Comments in the          *
    *                      dataset also result in incorrect        *
    *                      messages. Thus the server               *
    *                      does not start AutoException.           *
    *                                                              *
    *                      Automatic Exception Processing ends     *
    *                      with the message:                       *
    *                                                              *
    *                      "FPEV0263E DB2Z AUTOMATIC EXCP NOT      *
    *                       STARTED"                               *
    *                      - NO VALID THRESHOLD RECORDS"           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • 1. Now the server works correctly with comments included in a
       threshold dataset.
    
    2. The example threshold dataset has been replaced, and does
       not contain asterisks for warning- or problem thresholds.
       Thus performing "Exception Profiling" is no longer required
       to make all thresholds within the example threshold dataset
       valid.
    
    * The components of                                            *
    * IBM Tivoli OMEGAMON XE for DB2 Performance Expert on z/OS    *
    * V310 and IBM Tivoli OMEGAMON XE for DB2 Performance Monitor  *
    * on z/OS V310 have the following service level:               *
    *                                                              *
    * OMEGAMON Server:                                             *
    *    FPEV0000I  DATA SERVER INITIALIZATION BEGINS              *
    *    FPEV0114I  PTF BUILD IS 06.216                            *
    
    SYSMOD TITLE : AUTOEXCEPTION -  example threshold dataset
                   DGOETV41 does not work
    KEYWORDS     : AUTOEXCEPTION   dataset DGOETV41
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK25976

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-06-21

  • Closed date

    2006-08-04

  • Last modified date

    2007-05-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    DGOETV41 DGOMEXA0 DGORPSCA DGOVEPAI DGOVMSTR
    KD260HZ  KD260HZA KD260HZB KD260HZC
    

Publications Referenced
SC18964100SC18998100   

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK16875

       UP06/08/08 P F608

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
10 May 2007