IBM Support

PK24976: OBJECT COMPARE PANEL GOC14 REQUIREMENT FOR FIELD TO BE NON-BLANK CAUSES RC0012 ON T02DB2 FOR SPECIFY LOCATION NAME NON BLANK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • GOC14 panel requires Location name field to be NON-BLANK. This
    causes confussion and also might results in rc0012 for third
    step T02DB2 .
    

Local fix

  • apply ptf when available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Object Comparison Tool, who     *
    *                 use panel GOC14, amy be affected.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: GOC14 panel requires Location  name     *
    *                      field to be NON-BLANK. This  causes     *
    *                      confussion and also might result in     *
    *                      RC0012 for third step T02DB2 .          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    See Problem Description.
    

Problem conclusion

  • The NONBLANK limitation for target location has been removed.
    .*
    Apply the fix.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK24976

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-05-15

  • Closed date

    2006-08-03

  • Last modified date

    2006-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    GOC14
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • R710 PSY UK16890

       UP06/08/10 P F608

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]